2.3
Regular adjustment flow
2.3
Regular adjustment flow
2.3.1
Adjustment Timing
When you have changed paper (brand, weight, or size) in a tray
Tips
-
If you do not change paper in a tray for one or more days, make adjustments before outputting a job
(before the adjustment flow for each job).
2.3.2
Adjustment Order
- With scanner (Original Glass) mounted
Ad-
Adjustment item
just-
ment
order
1
Finely adjust the side guide plates of the paper tray (for PF-707/PF-
707m/PF-602m)
2
[Front] Adjustment
3
[Scan Meas.] Adjustment
- Without scanner (Original Glass) mounted
Ad-
Adjustment item
just-
ment
order
1
Finely adjust the side guide plates of the paper tray (for PF-707/PF-
707m/PF-602m)
2
[Front] Adjustment
3-a
[Rotate/Skew] Adjustment: Prioritizes the accuracy of the image position.
3-b
[Gap] Adjustment (Back side adjustment): Reduces adjustment items required
to make simple adjustments.
- With Intelligent Quality Optimizer IQ-501 mounted
Ad-
Adjustment item
just-
ment
order
1
Finely adjust the side guide plates of the paper tray (for PF-707/PF-
707m/PF-602m)
2
[AutoMeasure] Adjustment
AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L
2
Reference
page 2-7
page 2-10
page 2-20
Reference
page 2-7
page 2-10
page 2-30
page 2-15
Reference
page 2-7
page 2-37
2-4