Executing Calibration - Konica Minolta AccurioPress C2070 Daily Maintenance Manual

For operator
Hide thumbs Also See for AccurioPress C2070:
Table of Contents

Advertisement

3.6
Details of quality adjustment items
-
If controller calibration, page 3-6, page 3-3, or page 3-4 does not improve color stability, creating a pro-
file may help solve the problem.

Executing Calibration

Start Color Centro, and use the i1Pro2 instrument to perform calibration.
1
Connect the instrument to the computer.
Example: The i1Pro2 is connected.
% The device driver for the instrument must be installed on your computer beforehand. For details,
refer to the instrument's manual.
2
Start Color Centro and log in to the machine.
The Color Centro top screen is displayed.
3
Click [Calibration] on the top screen.
The [Calibration Manager] screen is displayed.
4
Check that the instrument to be used is displayed under [Calibration].
% If the correct instrument is not displayed, select the instrument to be used from the menu bar [Set-
tings] - [Instrument].
Example: Check that [Instrument: i1Pro2(M0)] is displayed.
AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L
3
3-77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents