3.6
Details of quality adjustment items
22
Compare the calculated average with the maximum density target value that the service representative
has informed.
When two values are same or close, end the adjustment.
When two values are extremely different, perform the following adjustment.
Acceptable target density range:
Y, M, C: from -5% to +5%, K: from -5% to +10%
Example: Maximum density target value
23
Change the adjustment value according to the comparative result of the calculated value and the max-
imum density target value.
% The change value of density differs according to the paper.
Reference:
The change value of density for POD gloss coat 128g/m
-Y: Δ0.006/step
-M: Δ0.01/step
-C: Δ0.013/step
-K: Δ0.01/step