4. CONFIGURATION OF EtherCAT CONNECTION

4.2.2 EtherCAT NIC setting

The following procedure shows how to configure the EtherCAT NIC setting.
The PLC must be started and connected before starting the following procedure.
• If the PLC has not been started
See "3.1.4 Starting PLC", and start the PLC.
• If the PLC is not connected
See Steps 1 and 2 in "3.1.5 Running a PLC program", and connect the PLC.
1. Double-click EtherCAT_Master (EtherCAT Master) in the Devices window to display
a window for the EtherCAT_Master configuration.
2. In Source Address (MAC) under EtherCAT NIC Setting in the General tab, enter the
MAC address of the LAN port used for EtherCAT. Alternatively, you can click Browse
and select the MAC address.
4-20