Operation Mode; Temperature Setting - Hitachi PC-ARFG-E Installation & Operation Manual

Wired remote controller
Hide thumbs Also See for PC-ARFG-E:
Table of Contents

Advertisement

OPERATION

3.3 OPERATION MODE

Heating mode is only available when the indoor unit supports
cooling and heating. Cooling only machine cannot support heating.
Operation mode setting
1 Press " " or " " to select "Mode".
2 Set the operation mode with "
mode is switched in the following order:
"Cool" ↔ "Heat" ↔ "Dry" ↔ "Auto" ↔ "Fan"
If dual setpoint is selected in auto mode, both cooling setpoint
and heating setpoint can be selected.
With Auto Cool/Heat mode, temperature setting is by default
managed as follows when operation mode changes:
Operation mode switches from cooling mode to heating mode:
Temperature setting = Heating temperature setting -1°C
Operation mode switches from heating mode to cooling mode:
Temperature setting = Cooling set temperature +1°C

3.4 TEMPERATURE SETTING

1 Press " " or " " to select "Temp".
2 By pressing "
", the temperature is increased by 0.5°C to a
maximum of 30°C.
By pressing "
", the temperature is decreased by 0.5°C.
3 Cooling, Dry, Fan operation: a minimum of 19°C.
4 Heating operation: a minimum of 17°C.
5
PMML0565 rev.1 - 04/2022
" or "
". The operation
?
N O T E
The function selection setting is required for "Auto" operation. Contact
your distributor for detailed information.
?
N O T E
Depending on the type and setting of the indoor unit, it may not be
possible to set the temperature by 1°F (0.5°C).
The max./ min. temperature may differ depending on the type of
indoor unit.
Minimum and maximum temperature set-point limits can be
configured by selecting a cooling lower limit and heating upper limit in
the "Function Selection" mode.
When the "Automatic Reset of Setting Temperature" function is
selected, the temperature is automatically returned to the preset
temperature after the temperature set-point change.
Contact your distributor for detailed information about "Automatic
Reset of Setting Temperature" and "Cooling Lower Limit Value and
Heating Upper Limit Value for Setting Temperature" functions.