Servicing and maintenance

11.
Servicing and maintenance
AUMA
Service & Support
11.1.

Preventive measures for servicing and safe operation

11.2.

Disconnection from the mains

40
Damage caused by inappropriate maintenance!
Servicing and maintenance must be carried out exclusively by suitably qualified
personnel having been authorised by the end user or the contractor of the plant.
Therefore, we recommend contacting our service.
Only perform servicing and maintenance tasks when the device is switched off.
AUMA offer extensive service such as servicing and maintenance as well as customer
product training. For the relevant contact addresses, please refer to <Addresses>
in this document or to the Internet (www.auma.com).
The following measures are required to ensure safe device operation:
6 months after commissioning and then every year
Carry out visual inspection:
Cable entries, cable glands, blanking plugs, etc. have to be checked for correct
tightness and sealing.
Respect torques according to manufacturer's details.
Check fastening screws between actuator and gearbox/valve for tightness. If
required, fasten screws while applying the tightening torques as indicated in
chapter <Assembly>.
When rarely operated: Perform test run.
For devices with output drive A: Press in Lithium soap EP multi-purpose grease
on mineral oil base at the grease nipple with a grease gun.
Lubrication of the valve stem must be done separately.
Figure 29: Output drive type A
[1]
Output drive type A
[2]
Grease nipple
Table 12: Grease quantities for bearing of output drive type A
Output drive
A 07.2
1)
Quantity [g]
1.5
1)
For grease at density r = 0.9 kg/dm³
For enclosure protection IP68
After continuous immersion:
Check actuator.
In case of ingress of water, locate leaks and repair, dry device correctly and
check for proper function.
If the device must be dismantled, e.g. for service purposes, it can be separated from
the mains without having to remove the wiring.
SAEx 07.2
SAEx 16.2 / SAREx 07.2
A 10.2
A 14.2
2
3
SAREx 16.2
A 16.2
5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAREx 07.2 – SAREx 16.2 and is the answer not in the manual?

This manual is also suitable for:

Saex 07.2 – saex 16.2Norm

Table of Contents