10.2.3. Regeneration failure

Note
The system has not regenerated for more than 99 days or 7 days if the controller type has
been set to day of week.
A
Perform a manual regeneration to reset the error code.
B
If the system is metered, verify that it is measuring flow by running service
water and watching for the flow indicator on the display.
C
If the unit doesn't measure flow, verify that the meter is working properly and its cable is well
connected.
D
Enter master programming mode.
E
Verify that the unit is configured properly.
F
Check that system capacity has been selected.
G
Check that day override is set properly.
H
Check that meter is identified correctly.
I
If the unit is configured as a day of week system, verify that at least one day is set ON.
J
Correct the setting as necessary.

10.2.4. Memory error

Note
The controller board has a memory failure.
A
Perform a master reset.
B
Reconfigure the system via master programming mode.
C
Step the valve through a manual regeneration.
D
If the error reoccurs, unplug the unit.
E
Put it into bypass.
F
Contact dealer.
Ref. MKT-IM-004 / A - 27.10.2016