Xantrex Freedom Xi 1000 Owner's Manual page 46

Freedom xi series
Table of Contents

Advertisement

Specifications
DC Input
Operating voltage range for all models
Safe non-operating voltage range
Nominal voltage for all models
Nominal current at full load
AC Output
Output voltage range
Continuous power
Continuous current
Surge power
Max short-circuit current
Frequency
GFCI protection for 120VAC models only
Wave shape
Peak efficiency
Full load efficiency
Regulatory Approvals
EMC and Safety
32
Freedom Xi 1000
10.5–16.5 VDC (low limit)
11.8–16.5 VDC (mid limit)
12.1–16.5 VDC (high limit)
0–24 VDC
12.5 VDC
92 ADC
Freedom Xi 1000
110–125 VAC
1.0kW @ 40 °C
8.3 A
2000 W
55 A peak
60 Hz
Yes
True Sine Wave
87%
82%
Freedom Xi 1000
ETL listed to CSA 107.1
UL458 and UL458 Marine Supplement (drip shield with product number 808-1050 required)
ABYC E11, A20, A25, A31
Freedom Xi 2000
10.5–16.5 VDC (low limit)
11.8–16.5 VDC (mid limit)
12.1–16.5 VDC (high limit)
0–24 VDC
12.5 VDC
200 ADC
Freedom Xi 2000
110–125 VAC
2.0kW @ 25 °C
16.6 A
4000 W
55 A peak
60 Hz
Yes
True Sine Wave
87%
82%
Freedom Xi 2000
Freedom Xi Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freedom xi 2000

Table of Contents