Xantrex Freedom Xi 1000 Owner's Manual page 24

Freedom xi series
Table of Contents

Advertisement

Freedom Inverter Configuration
To adjust the low battery shutdown setting:
By default the low battery shutdown voltage setting is set to
Low ("").
1.
Press and hold the Inverter Power button for five seconds.
2.
Press the Inverter Power button until the LED screen flashes
"" intermittently.
3.
Press the Select button once.
The LED screen will display the present (or most recent) low
voltage setting. For example, "" is for a low shutdown
voltage setting.

low setting = 10.5 V

middle setting = 11.8 V

high setting = 12.1 V
4.
Continue pressing the Select button to cycle through the three –
"", "" and "" settings until you reach the desired
setting.
5.
Press and hold the Select button for five seconds to make the
setting permanent.
10
To return all feature settings to factory default settings:
1.
Press and hold the Inverter Power button for five seconds.
2.
Press the Inverter Power button until the LED screen flashes
"" intermittently.
3.
Press and hold the Select button for five seconds to return all
feature settings to their factory default settings.
Freedom Xi Owner's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freedom xi 2000

Table of Contents