Set" Parameters - Smeg WD2145 User Manual

Instrument washers
Hide thumbs Also See for WD2145:
Table of Contents

Advertisement

6.3

SET" PARAMETERS

Set on the display.
To access this item press the Start/Stop button.
The Set item contains a number of setting parameters.
User level operators can only display the parameters and cannot modify any "Set" parameters.
Set PARAMETER
Detergent pump P1 dispensing rate.
Setting in ml/litre, with maximum threshold of 20 ml/litre.
-1
The default value of this parameter is 4ml/litre.
Maximum recommended quantity: 10ml/litre.
Increase and decrease with the Selection buttons.
Detergent pump P2 dispensing rate.
Setting in ml/litre, with maximum threshold of 20 ml/litre.
-2
The default value of this parameter is 2ml/litre.
Maximum recommended quantity: 10ml/litre.
Increase and decrease with the Selection buttons.
Detergent pump P3 dispensing rate.
(Option not available on WD2145)
Setting in ml/litre, with maximum threshold of 20 ml/litre.
-3
The default value of this parameter is 10ml/litre.
Maximum recommended quantity: 15ml/litre.
Increase and decrease with the Selection buttons.
Water hardness setting
Set the hardness in °f, in steps of 5. Range: 5-60°f. The default
-4
setting is 40°f.
Warning: Make sure that the value is actually the same as the
hardness of the water used.
Printer language
English by default, the language can be chosen from the
various options available
-6
German
dE
Demineralised water
The use of demineralised water can be activated or
-7
deactivated depending on whether or not the relative
connection has been made (Activated: dn, Deactivated: --)
Fan hours
The parameter indicates, to the nearest ten, the number of
absolute filter hours left before the maintenance message
-8
appears. The initial default setting is 500. (e.g. the display
shows "-8:50"). The value can be reset by an authorised
engineer.
Number of cycles
Indicates, to the nearest ten, the number of cycles left before
-9
the maintenance message appears. The initial default setting
is 900 (e.g. "-9:90").
The value can be reset by an authorised engineer.
User Manual
DESCRIPTION
French
Spanish
Fr
ES
WD2145-WD1160-WD4060-WD4190
Display and
Modification
Display and
Modification
Display and
Modification
Display and
Modification
Display and
Modification
Italian
English
It
En
Display and
Modification
Display Only
Display Only
POSSIBLE SUPERUSER ACTION
With set
With set
parameter
parameter
"-d=0"
"-d=1"
Display
Display
Display
Display and
Modification
Display and
Modification
Display and
Modification
Display Only
Display Only