5.3

"SET" PARAMETERS

Set on the display.
To access this item press the Start/Stop button.
The Set item contains a number of setting parameters.
Set
PARAMETER
Detergent pump P1 dispensing rate.
Setting in ml/litre, with maximum threshold of 10 ml/litre.
The default value of this parameter is 5ml/litre.
-1
Maximum recommended quantity with Smeg detergents:
10ml/litre.
Increase and decrease with the Selection buttons.
Detergent pump P2 dispensing rate.
Setting in ml/litre, with maximum threshold of 20 ml/litre.
The default value of this parameter is 3ml/litre.
-2
Maximum recommended quantity with Smeg detergents:
10ml/litre.
Increase and decrease with the Selection buttons.
Detergent pump P3 dispensing rate.
Setting in ml/litre, with maximum threshold of 20 ml/litre.
The default value of this parameter is 10ml/litre.
-3
Maximum recommended quantity with Smeg detergents:
15ml/litre.
Increase and decrease with the Selection buttons.
Water hardness setting
Set the hardness in °f, in steps of 5. Range: 5-60°f. The
-4
default setting is 40°f.
Warning: Make sure that the value is actually the same as
the hardness of the water used.
Automatic opening at end of cycle
The default setting on GW appliances is "On", but automatic
door opening can be disabled by changing the parameter to
-5
"OF".
If the option is enabled, the device door is opened
automatically at the end of the cycle.
Printer language
English by default, the language can be chosen from the
various options available
-6
German
dE
Demineralised water
The use of demineralised water can be activated or
-7
deactivated depending on whether or not the relative
connection has been made (Activated: dn, Deactivated: --)
Residual filter hours
The parameter indicates, to the nearest ten, the number of
absolute filter hours left before the maintenance message
-8
appears. The initial default setting is 500. (e.g. the display
shows "-8:50"). The value can be reset by an authorised
engineer.
User Manual
DESCRIPTION
French
Spanish
Fr
ES
GW1160 - GW4060 Series
Display Only
Display Only
Display Only
Display Only
Display Only
Display Only
Italian
English
It
En
Display Only
Display Only
POSSIBLE
POSSIBLE USER
SUPERUSER
ACTION
ACTION
Display and
Modification
Display and
Modification
Display and
Modification
Display and
Modification
Display and
Modification
Display and
Modification
Display and
Modification
Display Only
Page 38 - 75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw4060

Table of Contents