TEST
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
IEC 60255-5
Test
IEEE C37.90.3
IEEE C37.90.2
IEEE C37.90.1
IEEE C37.90.1
IEEE C37.90
IEEE C37.90
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Notes:
1. Only applicable to functional earth connections separated from the safety earth connection.
2. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")
www.RuggedCom.com

EMI and Environmental Type Tests

IEC 61850-3 EMI TYPE TESTS
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips & Interrupts
Damped Oscillatory
Mains Frequency Voltage
Ripple on D.C. Power Supply
Dielectric Strength
H.V. Impulse
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Description
ESD
Radiated RFI
Fast Transient
Oscillatory
H.V. Impulse
Dielectric Strength
Description
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
8-Port Managed Gigabit Ethernet Switch, 128-bit Encryption
Enclosure Contact
+/- 8kV
Enclosure Air
+/- 15kV
Enclosure ports
20 V/m
Signal ports
+/- 4kV @ 2.5kHz
D.C. Power ports
+/- 4kV
A.C. Power ports
+/- 4kV
Earth ground ports
+/- 4kV
3
Signal ports
+/- 4kV line-to-earth, +/- 2kV line-to-line
D.C. Power ports
+/- 2kV line-to-earth, +/- 1kV line-to-line
A.C. Power ports
+/- 4kV line-to-earth, +/- 2kV line-to-line
Signal ports
10V
D.C Power ports
10V
A.C. Power ports
10V
Earth ground ports
10V
3
Enclosure ports
40 A/m continuous, 1000 A/m for 1 s
D.C. Power ports
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
30% for 1 period, 60% for 50 periods
A.C. Power ports
100% for 5 periods, 100% for 50 periods
Signal ports
2.5kV common, 1kV diff. mode@1MHz
D.C. Power ports
2.5kV common, 1kV diff. mode@1MHz
A.C. Power ports
2.5kV common, 1kV diff. mode@1MHz
Signal ports
30V Continuous, 300V for 1s
D.C. Power ports
30V Continuous, 300V for 1s
D.C. Power ports
10%
Signal ports
2kVac (Fail-Safe Relay output)
D.C. Power ports
1.5kV DC
A.C. Power ports
2kVac
Signal ports
5kV (Fail-Safe Relay output)
D.C. Power ports
5kV
A.C. Power ports
5kV
Enclosure Contact
+/- 8kV
Enclosure Air
+/- 15kV
Enclosure ports
35 V/m
Signal ports
+/- 4kV @ 2.5kHz
D.C. Power ports
+/- 4kV
A.C. Power ports
+/- 4kV
Earth ground ports3
+/- 4kV
Signal ports
2.5kV common mode @1MHz
D.C. Power ports
2.5kV common, 1kV diff. mode@1MHz
A.C. Power ports
2.5kV common, 1kV diff. mode@1MHz
Signal ports
5kV (Fail-Safe Relay output)
D.C. Power ports
5kV
A.C. Power ports
5kV
Signal ports
2kVac
D.C. Power ports
1.5kV DC
A.C. Power ports
2kVac
Environmental Type Tests
Test Ad
Test Bd
95% (non-condensing), 55¡C , 6
Test Db
Tests Fc
Tests Ea
RuggedSwitch
Test Levels
2
Test Levels
Test Levels
Severity Levels
-40°C, 16 Hours
+85°C, 16 Hours
cycles
2g @ (10 - 150) Hz
30g @ 11mS
RuggedSwitch
RS940G
®
Severity Levels
4
4
x
x
4
4
4
4
3
4
3
3
3
3
N/A
N/A
N/A
N/A
3
3
3
4
4
3
N/A
N/A
N/A
N/A
N/A
N/A
Severity Levels
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Class 2
Class 2
RS940G