TEST
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
Induced (Conducted) RFI
IEC 61000-4-8
IEC 61000-4-29
Voltage Dips & Interrupts
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
Mains Frequency Voltage
IEC 61000-4-17
Ripple on D.C. Power Supply
IEC 60255-5
IEC 60255-5
Test
IEEE C37.90.3
IEEE C37.90.2
IEEE C37.90.1
IEEE C37.90.1
IEEE C37.90
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Notes:
1. Only applicable to functional earth connections separated from the safety earth connection.
2. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high,
5.
( e.g. shipboard application and for severe transportation conditions")
www.RuggedCom.com
4-Port Serial Device Server with Integrated 4-Port Managed Ethernet Switch

EMI and Environmental Type Tests

IEC 61850-3 EMI TYPE TESTS
Description
Enclosure Contact
ESD
Enclosure Air
Radiated RFI
Enclosure ports
D.C. Power ports
Burst (Fast Transient)
A.C. Power ports
Earth ground ports 3
Surge
D.C. Power ports
A.C. Power ports
D.C Power ports
A.C. Power ports
Earth ground ports 3
Magnetic Field
Enclosure ports
D.C. Power ports
A.C. Power ports
Damped Oscillatory
D.C. Power ports
A.C. Power ports
D.C. Power ports
D.C. Power ports
Dielectric Strength
D.C. Power ports
A.C. Power ports
H.V. Impulse
D.C. Power ports
A.C. Power ports
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Description
Enclosure Contact
ESD
Enclosure Air
Radiated RFI
Enclosure ports
D.C. Power ports
Fast Transient
A.C. Power ports
Earth ground ports3
Oscillatory
D.C. Power ports
A.C. Power ports
Dielectric Strength
D.C. Power ports
A.C. Power ports
Environmental Type Tests
Description
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
+/- 8kV
+/- 15kV
20 V/m
Signal ports
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
Signal ports
+/- 4kV line-to-earth, +/- 2kV line-to-line
+/- 2kV line-to-earth, +/- 1kV line-to-line
+/- 4kV line-to-earth, +/- 2kV line-to-line
Signal ports
10V
10V
10V
10V
40 A/m continuous, 1000 A/m for 1 s
30% for 0.1s, 60% for 0.1s, 100% for 0.05s
30% for 1 period, 60% for 50 periods
100% for 5 periods, 100% for 50 periods 2
Signal ports
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
Signal ports
30V Continuous, 300V for 1s
30V Continuous, 300V for 1s
10%
Signal ports
2kVac (Fail-Safe Relay output)
2kVac
2kVac
Signal ports
5kV (Fail-Safe Relay output)
5kV
5kV
+/- 8kV
+/- 15kV
35 V/m
Signal ports
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 4kV
Signal ports
2.5kV common mode @1MHz
2.5kV common, 1kV diff. mode@1MHz
2.5kV common, 1kV diff. mode@1MHz
Signal ports
2kVac
2kVac
2kVac
Test Ad
Test Bd
95% (non-condensing), 55°C , 6
Test Db
Tests Fc
2g @ (10 - 150) Hz
Tests Ea
RuggedServer™ RS401
Test Levels
Test Levels
Test Levels
Severity Levels
-40°C, 16 Hours
+85°C, 16 Hours
cycles
30g @ 11mS
RuggedSwitch
TM
Severity Levels
4
4
x
x
4
4
4
4
3
4
3
3
3
3
N/A
N/A
N/A
N/A
3
3
3
4
4
3
N/A
N/A
N/A
N/A
N/A
N/A
Severity Levels
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Class 2
Class 2
RS401