3.2

Visible Alarming Devices

The device provides visible alarm indicators through the touchscreen display and optional strobe.

3.2.1 Touchscreen Display

After the initial setup configuration, the touchscreen display shows a dashboard with the main function
buttons and tiles for the points that are enabled.
Notifications for all predictive warnings, alarms, and faults show on the dashboard.

3.2.2 Optional Strobe

The optional strobe provides a user-configurable visual indication of a gas leak.
For a list of approved parts and how to order them, refer to Section 13, "Ordering Information".
For installation instructions, refer to Section 15, "Appendix B: Installation of Optional Equipment".
3.3

Audible Alarming Devices

The device provides audible alarm indicators through the internal alarm and optional external horn.

3.3.1 Internal Horn

A horn inside the device provides an audible indicator of a gas leak. The level of sound output from
the internal horn is adjustable. To adjust the level of sound output, turn the sounder clockwise or coun-
terclockwise.

3.3.2 Optional External Horn

An optional external horn can be mounted in a location away from the device to provide an audible
indicator of a gas leak.
For a list of approved parts and how to order them, refer to Section 13, "Ordering Information".
For installation instructions, refer to Section 15, "Appendix B: Installation of Optional Equipment".
3.4

Optional External Alarm Activation and Silencing Stations

The device supports optional external stations for the activation and silencing of audible alarms.
Normally closed alarm activation and silencing switches can be wired in a single loop with a total
maximum loop length of 2500 ft (762 m).
For a list of approved parts and how to order them, refer to Section 13, "Ordering Information".
For installation instructions, refer to Section 15, "Appendix B: Installation of Optional Equipment".