7. Inlet Filter - Cleaning
WARNING! Isolate the electrical and water supplies before removing the cover. Mains
electricity connections are exposed when the cover is removed.
7.1. Unscrew the four cover retaining screws sufficient to remove the cover and
service tunnel.
Note! The cover retaining screws are captive and need not be removed.
7.2. Hold a wrench across the flats of the inlet connector assembly to prevent damage
to the connector, and unscrew the inlet filter.
7.3. Withdraw the inlet filter. Clean or renew as necessary.
7.4. Refit in reverse order. Ensure that the filter is screwed fully home.