Commissioning - Mira elite 2 Installation, Operation, Maintenance Manual

Pumped electric shower
Table of Contents

Advertisement

Section
9
1. Mira Elite 2
If you are unsure how electric showers work, please read through the Operation Section
before continuing.
1.1. Make sure that the START/STOP button is in the
outermost position and that the electrical supply has
been isolated.
1.2. Turn the BOTTOM control knob fully anticlockwise to
the full cold position.
1.3. Turn the water supply fully on at the isolating valve,
check that water is not leaking from the bottom of the
case.
1.4. Turn the TOP control knob to 'LOW'.
1.5. Switch on the electrical supply at the double pole
switch. The 'POWER' neon will provide a visual
indication that the electrical supply is connected.
1.6. Press the START button. Check that water flows freely
from the shower within a few seconds. If not refer to the
Maintenance Section. The water from the handset
will be at full force and at a cool temperature.
1.7. Turn the BOTTOM knob slowly clockwise. As the knob
is rotated the flow will be reduced and the temperature
will remain cool - this shows that the flow regulator
assembly is operating correctly. Return the knob
anticlockwise to full cold position.