4. Heater Tank - Removal and Installation
WARNING! Isolate the electrical and water supplies before removing the cover. Mains
electricity connections are exposed when the cover is removed.
4.1. Unscrew the four cover retaining screws sufficient to remove the cover and
service tunnel.
Note! The cover retaining screws are captive and need not be removed.
4.2. Remove the hose from the outlet connector and loosen the connection to the inlet
connector assembly.
4.3. To improve access to the terminals on the top of the tank, the terminal block may
be loosened by removing the fixing screw.
4.4. Remove the screws that hold the clamp bracket in position and remove the clamp
bracket.
4.5. Remove the screws that hold the flow valve and switch assembly and the heater
tank in position.
4.6. Carefully pull the flow valve,switch assembly and heater tank away from the
case.
4.7. Make a note of the positions of the wiring on top of the heater tank.
4.8. Remove the blue wire and associated solenoid wires.
4.9. Remove the brown and red wires from one side of the thermal switch and the
second brown wire from the other side of the thermal switch.
Caution! Do not press printed disc on the thermal switch as this will make the
component unserviceable.
4.10. Remove the fixing screw and remove the thermal switch and the green earth
bonding wire from the top of the heater tank.
4.11. Remove the red and black tank wires from the microswitches.
4.12. Separate the heater tank from the flow valve and switch assembly.
4.13. Remove the outlet connector from the heater tank.
4.14. Refit the components in reverse order. Make sure that the electrical wires are
installed in the correct positions. In particular the green earth bonding wire must
be reconnected above the thermal switch flange.