3.6.6 I/O Menu

The I/O Menu is used to configure the optional input and output device parameters.
Reset
This menu item is used to reset the I/O menu to factory defaults. Selections are: No, Yes.
External Input
This menu item is used to define a function to be controlled by an optional external input device
such as a foot switch.
Selections are:
Off
Tare
Zero
Print
Units
GNT
Accumulation
Start-Stop (S-S*)
Tare-Start-Stop (T-S-S*) = The first external input signal initiates a Tare function. The
Note: Start-Stop and Tare-Start-Stop are only available when the Relay Option is installed. When
selected, pressing the NEXT +/- button will have the same effect as if a switching signal was
received from an external device.
Input Beep
This menu item is used to enable or disable an audible signal each time an external signal is
received. Selections are: Off, On.
Relay Output
This menu item is used to define the relay output parameters. Selections are: Type, Sequence,
Contact.
Note: If the Relay option is not installed the OUTPUT menu and associated submenus are not
available for viewing or editing.
TYPE
This menu item is used to define the selection of normally open or closed relay functions.
Selections are:
O p e n
O p e n
O p e n
= The initial state of the Relay output is normally open.
O p e n
O p e n
Closed
= The initial state of the Relays output is normally closed.
= The external input is disabled.
= The external input initiates a Tare function.
= The external input initiates a Zero function.
= The external input initiates a Print function.
= The external input changes to the next available weighing unit.
= The external input simulates the function of the G/N/T button.
= The external input increments a weighment totalizing function.
= The first external input signal enables the output relay operation,
(Start). The second external input signal disables the relay
operation, (Stop).
second external input signal enables the output relay operation,
(Start). The third external input signal disables the relay
operation, (Stop).