Do not use where flammable or corrosive gas is present.
Leaked gas accumulating around the unit causes explosions and fire.
Make sure that you securely install the unit in a place that can fully withstand
both the unit's weight and its usage. Install the robot and switchbox on a workbench
60cm or higher above floor level, and install the robot in the center of the workbench. In
addition, for units with a cooling fan on the back, allow for 30cm or more
clearance between the back of the unit and the wall.
If installation is inadequate, the unit can drop or fall over causing injury and unit
breakdown. Also, inadequate installation causes overheating and fire.
Do not drop or jar the unit during transport and/or installation.
This causes injuries or damages the unit.
Use the unit in an environment between 0 and 40°C, with a humidity level of 20 –
90%, and without condensation.
Use outside of these conditions can cause unit malfunction.
Use the unit in an environment where no electrical noise is present.
Failure to do so causes unit malfunction or breakdown.
Use the unit in an environment that is not exposed to direct sunlight.
Direct sunlight causes unit malfunction or breakdown.