5-4) System Settings - FujiFilm RYB500S3-VBC User Manual

Faldic-beta series ac servo system ryb series gyc series gys series gyn series
Table of Contents

Advertisement

5
PARAMETERS

5-4) System settings

System setting parameters are described in the order of the parameter number.
System setting parameters #10 through #14
No.
Name
CONT 1 signal
10
allocation
CONT 2 signal
11
allocation
CONT 3 signal
12
allocation
CONT 4 signal
13
allocation
CONT 5 signal
14
allocation
System setting parameters #15 and #16
No.
Name
OUT 1 signal
15
allocation
OUT 2 signal
16
allocation
The following functions can be assigned to sequence input/output terminals.
n CONT signal allocation number
Setting
0
Not specified
1
Operation command
2
Reset
3
+ overtravel
4
- overtravel
5
Forced stop
6
P-action
7
Deviation clearance
External regenerative resistor
8
overheat
Anti-resonance frequency
9
selection 0
Anti-resonance frequency
10
selection 1
Setting range
0 to 10 (in 1 increments)
0: Not specified
2: Reset [RST]
4: - overtravel
6: P-action
8: External regenerative 9: Anti-resonance frequency
resistor overheat
10: Anti-resonance
frequency selection 1
Setting range
0 to 5 (in 1 increments)
0: Not specified
2: Alarm detection:
b-contact
4: Overtravel detection
Name
Page
-
[RUN]
5-18
[RST]
5-19
[+OT]
5-20
[-OT]
[EMG]
5-22
5-24
5-25
5-26
5-27
1: Operation command [RUN]
3: + overtravel
5: Emergency stop [EMG]
7: Deviation clearance
selection 0
1: Alarm detection: a-contact
3: Dynamic brake
5: Forced stop detection
n OUT signal allocation number
Setting
0
Not specified
1
Alarm detection: a-contact
2
Alarm detection: b-contact
3
Dynamic brake
4
Overtravel detection
5
Forced stop detection
5-16
Initial value
Change
1 [RUN]
Power
2 [RST]
Power
0
Power
0
Power
0
Power
Initial value
Change
1 Alarm
detect:
Power
a-contact
0
Power
Name
Page
-
5-28
5-29
5-20
5-22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents