8-3) State display mode

In the state display mode, the servo amplifier's current status and the alarm detection history can be
displayed.
Press the "MODE" key to display [
Mode
State display mode
(1) Operation mode
Indicates the operation status of the servo amplifier.
ENT (1 sec. or more)
Reference
When power is supplied to the servo amplifier, the operation mode of the state display mode is
displayed (with factory shipment setting).
The type of indication at power on can be changed by system parameter 28 setting.
] and then press the "ENT" key for more than 1 sec.
1. Operation mode
2. Alarm detection
3. Alarm history
ESC
System setting parameter #28
Setting
Display content
0
State display mode
1
Current alarm
2
Alarm history
Sub-mode
Indication
In base-off condition. The servomotor does not
have driving force and is coasting to stop.
The servomotor can rotate and pulse string
inputs are valid.
The servomotor can rotate and is operated in
the manual operation mode (test running).
The amplifier has detected an overtravel signal
in positive direction and stops.
The amplifier has detected an overtravel signal
in negative direction and stops.
The amplifier has received a forced stop signal
and stops with the speed zero.
Display
Setting
3
4
5
6
7
8
9
10
11
8-5
KEYPAD PANEL
Sub-mode indication
Sequence
Display content
Feedback speed
Actual torque
Peak torque
Pulse string frequency
Input signal
Output signal
OL thermal value
DB thermal value
Load inertia ratio
8