n Timing chart
Power-on timing chart
Internal control power
No energization
Main power supply
No energization
Amplifier initialization
RUN
RDY
Pulse string command
* Avoid turning on and off repeatedly.
Wait at least one minute before turning the power on again after turning it off.
700 ms
Energization
Energization
About 1 sec.
OFF
About 4 ms
OFF
Not supplied
Supplied
Appendix -5