8-6) Test Running Mode ・・・・・・・・・・・・・8-15 - FujiFilm RYB500S3-VBC User Manual

Faldic-beta series ac servo system ryb series gyc series gys series gyn series
Table of Contents

Advertisement

8-6) Test running mode
In the test running mode, keying on the keypad panel can rotate the servomotor or reset various settings
of the servo amplifier.
Press the MODE key to display [
running.
Mode
Test running mode
(1) Manual operation
The servomotor rotates while a key on the keypad panel is pressed. The servomotor speed is as per the
setting of parameter #29 and the acceleration/deceleration time is as per the setting of parameter #30.
* The servomotor rotates while the ∧ or ∨ key is held down.
System setting parameters #29 and #30
No.
Name
29
Speed setting (for test operation)
Acceleration / deceleration time
30
(for test operation)
] and hold down the ENT key for at least 1 second to execute test
Sub-mode
1. Manual operation
2. Alarm reset
3. Alarm history initialization
4. Parameter initialization
5. Phase-Z position adjustment
6. Auto tuning gain setting
ENT (1 sec or more)
ESC
ESC
Offline
Setting range
1 to 5000 [r/min] (in 1 increments)
0.000 to 9.999 sec.
(in 0.001 increments)
KEYPAD PANEL
Sub-mode indication
ENT
Rotation in positive direction
Rotation in negative direction
8-15
Relevant parameters
Parameters #29 and #30
-
-
Parameter #27
Parameter #18
Parameter #7
Initial value
Change
100
Always
0.100
Always
8