3-3) Servomotor - FujiFilm RYB500S3-VBC User Manual

Faldic-beta series ac servo system ryb series gyc series gys series gyn series
Table of Contents

Advertisement

3
WIRING

3-3) Servomotor

(1) Servomotor
Connect the power cable of the servomotor to the U, V and W terminals of the servo amplifier while
identifying the symbols.
Do not supply commercial power directly to the servomotor. If attempted, the magnet inside the motor
will be de-magnetized and the servomotor will not rotate.
CAUTION
The direction of rotation of the servomotor cannot be changed by changing the sequence of the
servomotor terminals. Change the parameter 4 setting to achieve this.
The wiring length between the servo amplifier and servomotor should be within 50 m long.
It is not permitted to perform ON/OFF of the wiring between the servo amplifier and servomotor using
magnetic contactors. It is not permitted to turning ON/OFF multiple servomotors with a single servo
amplifier.
Furthermore, it is not permitted to connect the following equipment along the wiring between the servo
amplifier and servomotor:
Phase advancing capacitor, various reactors, noise filter, surge absorber
Do not supply commercial power to the servomotor.
If attempted, the internal magnet will be de-magnetized and the
servomotor will not rotate.
U
V
W
3-10
U
V
W

Hide quick links: