Validation Checksum Error; Invalid Validation Command; Validation Parameter Error; Radio Busy Message - Tait TM8100 Protocol Manual

Computer-controlled, data interface, ccdi
Hide thumbs Also See for TM8100:
Table of Contents

Advertisement

Effect
2.7.2

Validation Checksum Error

2.7.3

Invalid Validation Command

2.7.4

Validation Parameter Error

2.7.5

Radio Busy Message

2.7.6

Command Not Accepted Message

60
CCR
The implementation exits the validation as soon as an error has been struck
- it will not check the parameters if the command does not pass the
checksum test.
If the input string does not have the correct checksum, a checksum error is
immediately reported and no further checks are done.
If the input string passes the checksum test but the identity contained is not
a recognised CCR command, an invalid command is reported.
If the input string passes the general message format but not the command
specific tests, a parameter error is sent. For details on validation rules see the
specific commands.
data length check
range check on message data
correct sequence of commands
If the input string passes both the general and command specific validation
criteria, it is processed only if the following conditions are true:
Radio is not in transmitting state
Radio is not busy processing the last sent command
The radio rejects the commands and returns the busy error code in these
instances.
Some commands trigger sequence errors if they are sent when the radio
cannot process the command, for example:
Radio is attempting to use a selcall command when there is no selcall
configuration defined.
This error is, for instance, sent if a selcall command is received, but the CCR
channel is not activated with a network using selcall signalling.
TM8100/TM8200 Computer-Controlled Data Interface (CCDI) Protocol Manual