Ultima X Sampling Module - Aspirated Model - MSA Ultima X Instruction Manual

Sampling module, dc aspirated model
Hide thumbs Also See for Ultima X:
Table of Contents

Advertisement

Table 1-1.
Performance Specifications
for Ultima X Sampling Module - Aspirated Model
ASPIRATOR AIR
Instrument grade air
REQUIREMENTS
MAXIMUM
30 PSIG (206 kPa)
ASPIRATOR
PRESSURE
MINIMUM
.6 CFM at 20 PSIG (137 kPa)
ASPIRATOR AIR
CONSUMPTION
MAXIMUM
.9 CFM at 30 PSIG (206 kPa)
ASPIRATOR AIR
CONSUMPTION
MAXIMUM POWER
1.8 watts at 9 to 30 VDC
CONSUMPTION
CABLE
Four conductor, shielded, 18 AWG (typical)
REQUIREMENTS
FOR ALL GASES
SAMPLE
30 seconds at 0.5 LPM with 50 feet (15.25 meters)
TRANSPORT TIME
of .180 (4.57 mm) ID sample tubing
NOMINAL SAMPLE
2 CFH (1 LPM)
FLOW RATE
MINIMUM SAMPLE
1 CFH (.500 LPM)
FLOW RATE
MAXIMUM SAMPLE
100 feet (30 meters)
TUBING LENGTH
MAXIMUM EXHAUST
20 feet (6 meters)
TUBING LENGTH
INLET FITTINGS
1/4" (6.35 mm) OD Tube Fitting
EXHAUST FITTING
1/4" (6.35 mm) OD Tube Fitting
CALIBRATION
1/4" (6.35 mm) OD Barbed Fitting
FITTING
OVERALL
9" x 6" x 5" (228.5 cm x 152.4 cm x 127 cm)
DIMENSIONS
WEIGHT
4.5 lbs. (2 kg)
RATING
Explosion-proof enclosure, Class I,
Groups A, B, C and D, Division 1, Hazardous Locations
ELECTRICAL
3/4-14 NPT
ENTRY
TROUBLE
0.6 Amps at 125 VAC
RELAY
0.6 Amps at 110 VDC
RATING
2 Amps at 30 VDC
1-4