Before use the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used.
MSA or authorized persons. Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator.
[thus keeping the lens largely fog-free] and then through the check valves into the nose cup. The exhalation air passes through the exhalation valve directly to the ambient air. Fig. 1 Overview mask/helmet combination Helmet Visor Adapter with tightening strap Helmet Connector with inhalation and exhalation valves Lens Ultra Elite-H Mask – Negative Pressure...
Part Number Marking [date code, serial number] CE-marking with notified body number [DEKRA EXAM, Zertifizierungsstelle Dinnendahlstr. 9, 44809 Bochum] X: ATEX classification A, B or C according to the Lens typ. EN standard, class Ultra Elite-H Mask – Negative Pressure...
DIN 58610:2006 for helmets see operating manual helmet 0158 DEKRA EXAM GmbH, Dinnendahlstr. 9, 44809 Bochum, Germany, Notified body number: 0158 The Declaration of Conformity can be found under the following link: https://MSAsafety.com/DoC Ultra Elite-H Mask – Negative Pressure...
Adjust the helmet according to the helmet’s operating manual. Grip the helmet with both hands with the chinstrap open. Pull the helmet from the forehead over the head. Close and slightly tighten the chin strap. Ultra Elite-H Mask – Negative Pressure...
Donning the Mask WARNING! In order to guarantee a proper fit for those wearing glasses, the Ultra Elite-H Mask spectacle kit must be worn since ordinary glasses cannot be worn under the mask. When fitting the mask in position the chin strap of the helmet must be loose. Remove chin piece if necessary.
Lift both hooks of the helmet adapter to the side and pull them back out of the helmet slots. Remove the mask to the front. Do not grip the mask by the exhalation valve! Remove the helmet. Ultra Elite-H Mask – Negative Pressure...
After cleaning check the two screws for the lens ring. Retighten the screws hand-tight if neces- sary. Cleaning/Disinfection with an Ultrasonic Cleaner When cleaning/disinfecting with an ultrasonic cleaner please follow the cleaning agent’s user instructions on this CD/DVD. Ultra Elite-H Mask – Negative Pressure...
Disinfect the mask using recommended disinfectant. Please observe the user instruction for the disinfectant. Thoroughly rinse mask in running water. Dry mask and components and reassemble mask in reverse order. Perform a tightness test (see chapter 5.5). Ultra Elite-H Mask – Negative Pressure...
Always use original parts from MSA. Repairs and maintenance must be carried out only by authorised service centres or by MSA. Changes to devices or components are not permitted and will result in loss of approval.
Perform a tightness test [ chapter 5.5]. Tightness Test of the Mask The testing of the masks for tightness is performed using an applicable MSA test device in accordance with the relevant operating manual. Fit mask tight onto the test device.
For the safekeeping of the mask the mask container should be used. This also applies to masks with installed filters, except CO and NO filters. MSA rubber products are protected by an anti-aging agent that can become visible as a light coating. This coating is harmless and can be removed during cleaning.