Rice Lake Enterprise 1280 Series Installation

Rice Lake Enterprise 1280 Series Installation

Single a/d scale card
Hide thumbs Also See for Enterprise 1280 Series:

Advertisement

1280 Enterprise Series
The Single A/D Scale Card (PN 164085) provides a single scale channel. The 1280 can support up to eight scales. The
configuration of each scale is stored both on the card and in the indicator's memory. The CPU board will rewrite the calibration
to the A/D scale card when replacing or swapping installed cards.
Manuals can be viewed and downloaded from the Rice Lake Weighing Systems website at
Warranty information can be found on the website at
The included parts kit contains items used for installation of the card. Items listed for stud grounding of the shields pertain to the
panel mount enclosure. See the 1280 technical manual (PN 167659) for more information on grounding the shield.
Part No.
14621
14822
15130
153883
15631
53075
166957
171801
January 19, 2018
4
2
Figure 1. Single A/D Scale Card Kit
Item No.
Part No.
1
163407
Board Assembly, 1280 Single Com
2
14822
Screw, Mach 4-40 NCx1/4
163409
Face Plate, Option Card
3
4
167191
Label, Single A/D Scale Opt 1280
Table 1 Single A/D Scale Card Kit Parts List
Nut, Kep 6-32NC HEX (used for stud grounding)
Screw, Mach 4-40 NC x 1/4 (secures card to to controller assembly)
Washer, Lock NO 6 Type A (used for stud grounding)
Connector, 5 Pos Screw Terminal (interface connector)
Cable Tie, 3 inch Nylon (secures cable in panel mount installation)
Clamp, Ground Cable Shield (used for stud grounding)
NTEP seal for the A/D card to prevent removal.
158208 - Screw, Mach 4-40 x 3/8 (2)
165927 - Clip, Load Cell Locking (1)
Ferrite Core, Snap on
Table 2 Parts Kit (PN 163782)
www.ricelake.com/warranties
1
3
Description
Description
www.ricelake.com
Qty
1
1
1
1
Qty
1
1
1
1
4
1
1
1
PN 164652 Rev D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Enterprise 1280 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rice Lake Enterprise 1280 Series

  • Page 1 The CPU board will rewrite the calibration to the A/D scale card when replacing or swapping installed cards. Manuals can be viewed and downloaded from the Rice Lake Weighing Systems website at www.ricelake.com Warranty information can be found on the website at www.ricelake.com/warranties...
  • Page 2 Always disconnect power before opening the indicator. Option card is not hot swappable. WARNING Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when working CAUTION inside the indicator enclosure. 1. Open the indicator as instructed in the 1280 technical manual. 2.
  • Page 3 The slot of the controller assembly selected for the installation of the card determines the scale channels that can be Note associated to a scale number. Slot 1 = Slot 1 Channel 1 Slot 2 = Slot 2 Channel 1 Slot 3 = Slot 3 Channel 1 Slot 4 = Slot 4 Channel 1 Slot 5 = Slot 5 Channel 1...
  • Page 4 Specifications subject to change without notice. Rice Lake Weighing Systems is an ISO 9001 registered company. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 www.ricelake.com...

This manual is also suitable for:

164085

Table of Contents