Application Setup and Configuration
Parameter
Default
System Time and
Current Time/Date
Date
System Password
""
Clear Transactions
-
1.11.3

Recipe Batching Application

The 1280 formula batching application is included with the 1280 standard firmware. Upon startup, the softkeys
and
are available.
Recipe
Setup Menu
Recall a Recipe
1. Press the
softkey. The system prompts
Recipe
2. Enter the recipe ID and press
3. If the ID is not found, the system prompts
of the recipe information and updates the display.
Process a Batch
• The system will stop the batch if the
turns off all outputs.
The Emergency Stop Switch is sold separately. See the 1280 Technical Manual for batching switch wiring
instructions.
• To restart a batch at a paused step, turn the
• To abort and exit the batching sequence during a paused batch, turn the
switch.
Abort-Run-Start
To prevent personal injury and equipment damage, software-based interrupts must always be supplemented
WARNING
by emergency stop switches and other safety devices necessary for the application.
See the 1280 Technical Manual for more information on batching operations.
1. Ensure the scale is empty and zeroed.
2. If the displayed recipe is incorrect, perform the recall a recipe procedure described above.
3. Pull out the
Emergency Stop
4. The system will do the following things:
• Verify the weight is below the empty weight value
• Tare the scale
• Activate the output for the first ingredient until its target and preact weight value is met
• Capture and record the stable weight of the just added ingredient
• Activate the discharge scale output until the weight drops below the empty weight value. It will maintain
the output for the discharge time. If the discharge time is set to zero, the system will not perform a
discharge.
• Print a ticket and return to step 1
Softkey
Time and Date of that displays on the 1280.
Setup Password
Allows an operator to change the password that is required for entry
into the Setup Menu. If the password is set to nothing, the system will
not prompt for a password when the Setup Menu softkey is pressed.
Clear Trans
Allows an operator to clear the transaction database.
Table 1-7. Counting Application Setup and Configuration
Enter Recipe ID
.
Enter
Recipe NOT Found - Retry
Emergency Stop
Emergency Stop
switch and use the
Abort-Run-Start
Description
.
. If the ID is found, the system recalls all
switch is turned off while running a batch. The system also
switch on and use the
Emergency Stop
switch to start.
switch.
Abort-Run-Start
switch off and use the
Introduction