2
Making Measurements

Performing Temperature Measurement

Temperature measurement function is only available for U1212A and U1213A
only.
The bead-type thermocouple probe is suitable for measuring temperatures from
NOTE
–20 °C to 204 °C in PTFE-compatible environments. Above this temperature
range, the probe may emit toxic gas. Do not immerse this thermocouple probe in
any liquid. For best results, use a thermocouple probe designed for specific
application — an immersion probe for liquid or gel, and an air probe for air
measurement. Observe the following measurement settings:
– Clean the surface to be measured and ensure that the probe is securely
– When measuring above ambient temperatures, move the thermocouple
– When measuring below ambient temperatures, move the thermocouple
– Place the clamp meter in the operating environment for at least 1 hour as the
Do not bend the thermocouple leads at sharp angles. Repeated bending
CAUTION
over a period of time can break the leads.
Steps (see
1 Set the rotary switch to Ω.
2 Press Shift twice to select temperature measurement.
3 Connect the thermocouple adapter (with the thermocouple probe connected
4 Touch the measurement surface (device under test) with the thermocouple
48
touching the surface. Remember to disable the applied power.
along the surface until you get the highest temperature reading.
along the surface until you get the lowest temperature reading.
clamp meter is using non-compensation transfer adapter with miniature
thermal probe.
Figure 2-8
on page 49):
to it) into input terminals
probe and read the display.
Keysight U1211A, U1212A, and U1213A User's and Service Guide
(red) and COM (black).

Advertisement

Table of Contents
loading

This manual is also suitable for:

U1212aU1213a

Table of Contents