20 Installation
Press Enter ().
19.
The Welcome to Linux and login information window appears.
(more...) ]
You can press Ctrl+Alt+Del to reboot the computer.
After running the BIOS self-test and initialization, the computer should prompt with "LILO"; after 5
seconds, it should automatically boot up the computer and start running the TM-2000 application.
Welcome to Linux 2.4.17-rtha15.
demo_tm login:
Press Ctrl+Alt+Delete keys at the same time to reboot the TM-2000.
20.
TIP: To prevent the unit from booting from the CD again remove the CD from the unit. When the computer monitor
goes blank during the reboot press the eject button on the drive and the unit will release the CD.
Press Enter () to log into the unit (no password needed).
21.
NOTE:
tm1 login:
tm2 login:
tm_solo login:

Updating the TM-2000/MTM-2000 Software

IMPORTANT:
In order to update the TM-2000/MTM-2000, the following files are required:
update_tm.sh
one or more update files, typically with a name such as to_v880.tgz
These must be copied to a CD.
To perform an update, do the following:
Log onto the TM/MTM console as the user root.
1.
A line or two of information displays followed by a prompt, similar to root@tm1~#.
NOTE: A password may have been set for this user when the software was initially installed.
Shut down the TM-2000/MTM-2000 by running /tm/stop_tm all.
2.
Several lines of output appears followed by another prompt.
Insert the CD containing update_tm.sh and the first update file in the CD-ROM drive.
3.
Enter the command mount /cd.
4.
Enter the command sh /cd/update.sh.
5.
This copies the files to the hard drive.
When the update is complete, remove the CD.
6.
Update complete. you must now reboot the computer in order to restart the TM-2000 message appears.
Enter the command unmount /cd.
7.
Remove the CD from the drive.
8.
Reboot the computer.
9.
TIP:
You can either use the DOS reboot sequence (Ctrl+Alt+Delete) or you can enter the command shutdown -now.
Bosch Security Systems, Inc.
(if the Trunk Master was setup to be the active unit by default).
(if the Trunk Master was setup to be the standby unit by default).
(if the Trunk Master was setup to be a stand-alone unit).
User Manual