Show Control Settings

In [Setup]>{System}>{Show Control}, you can adjust settings for MIDI Show Control, time code
(MIDI or SMPTE), analog, and serial functions. See
Show Control Setup
This section allows you to adjust settings for MIDI show control, time code (MIDI or SMPTE), analog,
and serial functions. For more information on using show control with your system, see
Family Show Control (on the previous page)
Smpte
{SMPTE Time Code Rx}
This button is used to control whether your console can receive SMPTE time code. Choosing "Dis-
abled" will disable all time code lists that have a SMPTE source. The default for this setting is
"Enabled".
{Resync Frames}
This button allows you to configure how many frames need to be synced before time code starts run-
ning. Frames can be from 1-30. Default is 2 frames.
MIDI
{MSC Receive}
This button toggles the setting for receiving MIDI Show Control from an external source between
"Enabled" and "Disabled". The default setting is "Disabled".
{MIDI Rx Source ID}
This setting allows you to choose the devices from which the console will receive MIDI. When set,
the console will respond to MSC data from any Net3 gateway that has a matching "ACN MIDI Rx
ID." Gateways will send the MIDI data over an ACN connection. When built-in MIDI ports are avail-
able, the setting needs to match or at least contain the MIDI Rx ID.
For Example:
{MIDI Cue List}
MIDI Cue List specifies the cue list that the console will use to send MSC data. If left blank and MSC
Tx is enabled, all cue lists will generate MSC events. Otherwise, only the particular list (or lists) selec-
ted will fire MSC events.
{MSC Transmit}
This setting, when enabled, allows the console to send MSC messages for actions taken on the con-
sole, such as cue actions, macros firing, and submaster bumps. The default setting is "Disabled".
Show Control
{MIDI Rx Source ID} [2] [5] [Enter]
{MIDI Rx Source ID} [1] [Thru] [1][0] [Enter]
Show Control Setup (below)