ETC Installation Manual
QuickTouch+ Mk2 Control Panel and Electronics
System Riser
Legend
MCX
E-stop
E-stop Buttons
Up to 4 in a
chain
Terminate Wiring
Terminate your control cables for the E-stop and MCX connectors before connecting them to the
headers on the electronics board.
• Use Cat 5e or better (Cat 6 or Cat 7)
• Use Shielded Twisted Pair (STP) cable
• Unshielded Twisted Pair (UTP) cable must be run in continuous grounded metal conduit
Note:
The E-stop header on the electronics board ships with the termination jumper installed. If your
system does not have any external E-stop stations, leave the jumper installed. If you have external
E-stop stations, move the jumper to the last stop in the chain.
Control Wiring Diagram
The color code order of wires is the same for both motor communication (MCX) and E-stop,
though the data is different. Use the following diagram to determine the proper wiring order
when terminating the control wires.
1
2
3
Circuit
4
Board
Mount
5
6
7
8
QuickTouch+ Mk2 Control Panel and Electronics
QuickTouch+ Mk2 Controller
Optional
Remote Control
Installation must follow all national and local codes for electrical equipment.
MCX
E-Stop
W/BLU
1
+V (Supply)
24V Supply
BLU
2
+V (Supply)
LED Supply
W/ORG
D- (MCX Bus)
Deadman
3
ORG
D+ (MCX Bus)
E-stop Source
4
W/GRN
GND
Smart
5
GRN
Deadman
E-stop Monitor
6
W/BRN
GND
GND
7
BRN
E-stop
E-stop Return
8
Rigging System Power Injector
Rigging System
Power Injector
For variable-speed motors
OR
Power and Control
Distribution (PCD) boxes
Up to 12 motors
W/BLU
BLU
W/ORG
ORG
W/GRN
GRN
W/BRN
BRN
Page 3 of 7
Power and Control
Distribution (PCD) boxes
Up to 12 motors
ES1
ETC
Need help?
Do you have a question about the QuickTouch+ Mk2 and is the answer not in the manual?