Contact Closure (remote trigger connector)
Allows you to set the Group and Address In values for the remote trigger input on the back of your
console. The contact closure only reports on/off even though it is considered an analog input.
Note:
14+15. See the diagram below.
Relay Out
Allows you to assign the Relay Out Source ID and the Relay Out Address.
OSC
{OSC RX}
Globally enables receiving OSC.
{OSC RX Port Number}
This setting specifies the UDP port that the console will listen to for OSC receiving strings.
Note:
that when setting port numbers on your external device that they should be set to the
opposite of what Eos is set. For example, if {OSC TX Port Number} on Eos is set to 8000,
then the RX (incoming) port on your external device needs to be set to 8000, and vice versa.
{OSC Cue Recv String}
Allows the user to specify a different incoming OSC string format for integration with other applic-
ations. Use %1 in the string format as cue number and %2 as the cue list number.
{OSC TX}
Globally enables transmitting OSC.
Show Control
The contact closures require DC voltage, which is supplied by the console on pins
ETC recommends using 8000 and 8001 respectively for port numbers. Remember