Troubleshooting

Device Fail / Active Faults

If a device on the panel is not installed correctly or has been lost from the bus, a device fail occurs. An
example of each fault is as follows:
Failure on the panel: Control Panel, Battery Fault
Keypad address 3 failure: Device 3, Device Fail Kpd
Internal/External Tag Readers address 2 failure: Device 2, Device Fail Trd
Remote Input Expander address 0: RIX-00, Device Fail RIX
Remote Output Expanders address 0: ROX-00, Device Fail ROX
If a location name is entered for a device, the location is displayed on the keypad instead of the
address, for example instead of Device 3 for the Keypad, it would display Entrance Corridor.

System Faults and Troubleshooting

Table 11 - Communications Faults
Fault
MODEM FAULT
LINE FAULT
CALL FAIL TO ARC
DIGI LINE FAULT
DIGI Call Fail 100
64
Enforcer Installation Guide
Description
The panel is unable to see the Digi Modem.
There is no communication path to the modem.
Call to ARC has failed.
This is a communication problem, which is rarely
caused by an equipment fault. Most likely related
to hand shake and kiss off frequency set up at
receiver.
PSTN Line Fault signalled by device wired into
an input programmed as Line Fault.
Call to ARC from device using End Station DIGI
pins has failed.
Solution
If modem not present, ensure that Disable Digi
option is set to YES and Download by is set to
NONE or RS232.
If present, but not detected, check Digi Modem
cable is connected correctly.
Ensure the modem has adequate signal in order
to communicate. If there is a physical line to the
modem, make sure it is connected securely at
each end.
Check ALL call details are programmed
correctly. Ensure signaling format is correctly set
for ARC receiver.
Check for faults on third-party signalling devices
wired to the panel.
Ensure a 'Line Fault' timer is programmed.
Check that all communication devices on the
panel have a valid signal.