E T C S o u r c e F o u r L E D Q u i c k G u i d e

DMX Profiles

Lustr +, Series 2 Lu str, Ser ies 2 Daylight HD, Ser ies 2 Tungsten HD, and Studio HD
DMX
Profile
Channels
Direct
RGB
(Ch. 4 not
HSI
HSIC
Studio
(Ch. 4 not
Additional profile options (on following page)
Plus 7
Strobe
Sou rc e Fo ur LED Pr of i le
DMX
Channel Assignments
Channel
See
assignments in direct
10
mode
chart below
1-Red
2-Green
6
3-Blue
4 - n/a
used)
5 - Strobe
6-Fan Control
1 – Hue (coarse)
2 – Hue (fine)
3 - Saturation
6
4 - Intensity
5- Strobe
6-Fan Control
1 – Hue (coarse)
2 – Hue (fine)
3 - Saturation
7
4 - Intensity
5 - Strobe
6 - Fan Control
7-Color Point (CCT)
1 – Intensity
2 – Color Point (CCT)
6
3 - Tint
4 - n/a
used)
5 - Strobe
6 - Fan Control
Seven additional precision color-control override channels are available for
use with RGB, HSI, and HSIC input profile settings. For example HSI with
'Plus 7' enabled becomes an 15-channel profile:
Plus7 profile
See
options
chart below
Variable strobe control: 0% is no strobe. The fixture output will strobe more
rapidly as the strobe channel value approaches 100%.
Direct control of each individual color with a
separate master intensity channel. Color
calibration of LEDs is not active in this mode.
The ten-channel profile will produce the highest
quality color cross fades.
Effectively addresses all seven colors via three
channels of control. RGB profile will produce
medium quality color cross-fades
High resolution hue (two channels), saturation,
and intensity control.
HSI mode will produce color cross-fades around
the color space.
High-resolution hue, saturation, and intensity
control as above, with the addition of a color
point channel to adjust the color temperature of
the fixture in both white light and color. Color
cross-fade performance is the same as HSI.
Controls fixture as a white light unit. If no DMX
is present, (i.e. console input), a fixture can be
adjusted for these three parameters on the U/I
at the back of the unit.
The desired color and intensity are achieved by
using the HSI or RGB channels
Placing the Plus7 channel at a value over 51%
gives the fixture additional channels in its profile.
Channels 9-15 represent the native colors of the
fixture and allow the operator to adjust individual
color channels to fine tune the color output.