Room Switcher Detailed Configuration Options
NetLinx Page Options
TABLE 25
Command
Description
Enable
Click to enable/disable NetLinx on this device.
Device Status
This status field will show the device to be Online, Connected, Offline, or Unknown.
Master Mode
Select Auto, Listen, or URL.
IP/URL
Enter the address of the Master Controller.
Port
This field should always be set to 1319.
Device Number
Defaults to a dynamic device number. May be set to a static range (e.g., 8000).
System Number
Determines which system to connect. This setting is dependent upon the Master Mode selected (see above).
• If Master Mode is set to Auto, the System Number is set and the system discovers the Master Controller's IP
address.
• If Master Mode is set to Listen, the device connects to any Master Controller.
• If Master Mode is set to URL, the IP of the Master Controller is set.
Username
Username for the Master Controller.
Password
Password for the Master Controller.
Save button
Click to save settings made on this page.
46
N7142 User Manual