Superior SSBV-3530CNM Installation Instructions Manual page 20

B-vent ssbv-35/40 series
Table of Contents

Advertisement

WARNING
This conversion kit shall be
installed by a qualifi ed service
agency in accordance with the
manufacturer's instructions and
all applicable codes and require-
ments of the authorized having
jurisdiction. If the information
in these instructions is not fol-
lowed exactly, a fi re, explosion
or production of carbon monox-
ide may result causing property
damage, personal injury or loss
of life. The installation is not
proper and complete until the
operation of the converted appli-
ance is checked as specifi ed in
the owner instructions supplied
f i r e - p a r t s . c o m
with the kit. The qualifi ed service
agency performing this installa-
tion assumes responsibility for
this conversion.
IMPORTANT
CANADA ONLY
The conversion shall be carried
out in accordance with the require-
ments of the provincial authorities
having jurisdiction and in accor-
dance with the requirements of
the CAN1-B149.1 And B149.2
Installation code.
20
AVERTISSEMENT
Cet équipement de conversion
sera installé par une agence
qualifi ée de service conformé-
ment aux instructions du fabri-
cant et toutes exigences et codes
applicables de l'autorisés avoir
la juridiction. Si l'information
dans cette instruction n'est pas
suivie exactement, un feu, explo-
sion ou production de protoxyde
de carbone peut résulter le
dommages causer de propriété,
perte ou blessure personnelle
de vie.
L'agence qualifiée
de service est esponsable de
l'installation propre de cet
équipment. L'installation n'est
pas propre et compléte jusqu'à
l'opération de l'appareil converti
est chéque suivant les critères
établis dans les instructions de
propriétaire provisionnées avec
l'équipement.
IMPORTANT
LE CANADA SEULEMENT
La conversion devra être effec-
tuée conformément aux recom-
mandations des autorités pro-
vinciales ayant juridiction et
conformément aux exigences du
code d'installation CAN1-B149.1
ET.2.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Gas conversion kits are available to adapt the
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete the
task including labeling that must be affi xed to
ensure safe operation.
Kit part numbers are listed here and the following
steps detail the conversion procedure.
Step 1. Turn off the gas supply to the appliance.
Remove the front glass door/frame from the
appliance. Access the control compartment.
Step 2. Carefully remove the logs. Exercise care
so as not to break the logs.
Step 3. Locate the screws securing the burner
assembly to the appliance. Remove the burner
assembly and retain the securing screws.
Step 4. Millivolt Appliances - SIT Systems
a. See Figure 36 and the instructions
provided with the kit. Using a Torx T20,
tool or or standard fl at screwdriver remove
and discard the three pressure regulator
mounting screws. Remove the pressure
regulator, spring, poppet, diaphragm and
bushing. Discard all removed components.
Ensure the rubber gasket installed on the
back of the replacement pressure regulator
is properly positioned and install the new
pressure regulator using the new screws
supplied with the kit. Tighten screws to 25
In. lb. torque.
SIT Millivolt Gas Valve
Pressure
Regulator
Remove
These
Components
Figure 36