Superior Merit SLDVT-30NM Care And Operation Instructions Manual

Sldvt direct-vent gas fireplaces merit series

Advertisement

P/N 506010-04 Rev. A 04/2013
This manual is part of a set of two supporting this product.
Refer to P/N 506009-04 for Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 506223-59.
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
L'information de sûreté importante . . . . . . . . . . . . . . . 3–4
[EN FRANÇAIS]
Apposition des mises en garde relatives à la sécurité d'utilisation . . . . 5
Información importante de seguridad . . . . . . . . . . . . . . 3–4
[EN ESPAÑOL]
Colocación de advertencias de seguridad en operación . . . . . . . . . . . . 5
Wait...
INSTALLER: Leave this manual with the appliance.
DON'T
THROW
CONSUMER: Retain this manual for future reference.
IT AWAY!
INSTALLATEUR : Laissez cette notice avec l'appareil.
This manual contains
important operating
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
and safety
information.
WARNING / AVERTISSEMENT / AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
CARE AND OPERATION INSTRUC TIONS
SLDVT Direct-Vent
Gas Fireplaces
MODELS
SLDVT-30NM
SLDVT-30PM
SLDVT-35NM
SLDVT-35PM
Report No. 100353019PRT-001
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
MILLIVOLT:
SLDVT-40NM
SLDVT-40PM
SLDVT-45NM
SLDVT-45PM
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
ELECTRONIC:
SLDVT30NE-2
SLDVT35NE-2
SLDVT40NE-2
SLDVT45NE-2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Merit SLDVT-30NM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior Merit SLDVT-30NM

  • Page 1 CARE AND OPERATION INSTRUC TIONS SLDVT Direct-Vent ™ Gas Fireplaces P/N 506010-04 Rev. A 04/2013 MODELS MILLIVOLT: ELECTRONIC: This manual is part of a set of two supporting this product. Refer to P/N 506009-04 for Installation Instructions. SLDVT-30NM SLDVT-40NM SLDVT30NE-2 Ce manuel est disponible en francais, simplement SLDVT-30PM SLDVT-40PM...
  • Page 2: Table Of Contents

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® Thank you for your purchase. We appreciate your business! Safety and Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 3 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® [FRENCH] [SPANISH] La sécurité et Seguridad y votre foyer su chimenea Toutes les parties de votre foyer ¡Todas las partes de la chimenea Lennox Hearth Products deviennent Lennox Hearth Products se ponen EXTRÊMEMENT CHAUDES !
  • Page 4: Important Safety Information

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué...
  • Page 5: Attaching The Safety-In-Operation Warnings

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS ATTACHING SAFETY-IN-OPERATION APPOSITION DES MISES EN GARDE RELATIVES COLOCACIÓN DE ADVERTENCIAS DE WARNINGS À LA SÉCURITÉ D’UTILISATION SEGURIDAD EN OPERACIÓN Your fireplace has been furnished with safety instruc- Votre foyer a été...
  • Page 6: Appliance Installation, Service, And Maintenance Notices

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® Appliance Installation, Service, Appliance Operation Notices Warranty Information and Maintenance Notices Your gas appliance is covered by a limited Do not operate appliance with the glass twenty-year warranty. You will find a copy front removed, cracked, or broken.
  • Page 7: General Information

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® GENERAL INFORMATION Gas Pressure Requirements Orifice Sizes (All Models) (Sea Level to High Altitude – All Models) The fireplace models covered in this manual Gas pressure requirements are listed in...
  • Page 8: Operation/Care Of Your Appliance

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® OPERATION AND CARE OF YOUR APPLIANCE On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below WARNING the glass panel enclosure.
  • Page 9: Variable Flame Adjustment

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® Variable Flame Height Adjustment Electronic Appliances Main Gas Control Knob Gas Inlet To light electronic appliances refer to the detailed All millivolt and electronic appliances are lighting instructions found on Pages 23 and equipped with a variable gas control valve.
  • Page 10: Maintenance

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® MAINTENANCE Replacing Logs Note: Clean glass after first two weeks of opera- tion (after Burn-In period is over) and then only If the logs become damaged by accident or when necessary and when the fireplace is cool.
  • Page 11: Front Glass Enclosure Panel, Removal And Installation

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® Front Glass Enclosure Panel, Removal Installing the Glass Enclosure Panel WARNING and Installation 1. Retrieve the glass enclosure panel. Visually Any safety screen or guard inspect the gasket on the back side of the...
  • Page 12 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® INSTALL VOLCANIC STONE, WARNINGS Glowing Embers GLOWING EMBERS, AND LOGS Separate into Quarter • DO NOT attempt to install the Size (separate) Pieces NOTE: Turn off all electricity to the appli-...
  • Page 13 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® SLDVT-30 AND SLDVT-35 LOG PLACEMENT Number Description Left Front Log Right Front Log Left Rear Log Right Rear Log Catalog Number for the entire log set: H7244 Position the individual logs as shown below.
  • Page 14 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® SLDVT-40 LOG PLACEMENT Number Description Ember Chunk Left Front Log Right Front Log Left Rear Log Right Rear Log Catalog Number for the entire log set: H7245 Position the individual logs as shown below.
  • Page 15 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® SLDVT-45 LOG PLACEMENT Number Description Left Front Log Right Front Log Center Log Left Rear Log Right Rear Log Catalog Number for the entire log set: H7547 Position the individual logs as shown below.
  • Page 16 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance...
  • Page 17: Millivolt Appliance Checkout

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® Burner Air Shutter Adjustment Procedure Burner Air Shutter Adjustment Proper Pilot Flame Appearance Igniter Rod Pilot Hood WARNINGS Adjustment Set-Screw Adjustment • Air shutter adjustment should Thermocouple...
  • Page 18: Ordering Replacement Parts

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® ORDERING REPLACEMENT If you encounter any problems or have any Please call Lennox Hearth Products for the questions concerning the installation or ap- phone number of your nearest LHP dealer,...
  • Page 19: Accessory Components

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® ACCESSORY COMPONENTS ON/OFF and Timer Controls Thermostatic Controls Feature a timed ON/OFF mode as well as manual ON/OFF operation. Feature a thermostatic ON/OFF mode as well as manual ON/OFF operation.
  • Page 20 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® ACCESSORY COMPONENTS (continued) Barrier Screen Panel Kit This easy to install optional screen panel installs over the standard glass enclosure panel and provides a bar- rier to prevent direct contact with the hot glass surface.
  • Page 21 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® ACCESSORY COMPONENTS (continued) Touch-Up Paint Kit Repair of minor scratches and discoloration of the Forced Air Kit appliance black painted surfaces may be accomplished with the touch-up paint kit.
  • Page 22: Lighting Instructions - Millivolt

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
  • Page 23 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 24: Lighting Instructions-Electronic

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® LIGHTING INSTRUCTIONS—ELECTRONIC FOR YOUR SAFETY, READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
  • Page 25 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® INSTRUCTIONS D’ALLUMAGE—ELECTRONIC POUR PLUS DE SÉCURITÉ, LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 26: Maintenance Schedule

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® MAINTENANCE SCHEDULE Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance. Annually (Before the onset of the Burning Season)
  • Page 27: Troubleshooting Guide - Millivolt

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® TROUBLESHOOTING GUIDE: MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, make sure the external gas shut off valve (located at gas supply inlet) is in the “ON”...
  • Page 28: Troubleshooting Guide - Electronic

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® TROUBLESHOOTING GUIDE: ELECTRONIC GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, make sure the external gas shut off valve (located at gas supply inlet) is in the “ON”...
  • Page 29: Replacement Parts List

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® REPLACEMENT PARTS LIST Item No. Description SLDVT-30 SLDVT-35 SLDVT-40 SLDVT-45 Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty. Hood H7568 H7266 H7267 H7569...
  • Page 30: Replacement Parts

    SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS ® REPLACEMENT PARTS SIT Electronic Valve Components SIT Gas Controls (Ref.) Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents