Step 9. CHECKING APPLIANCE
OPERATION
With the gas line installed, run initial system
checkout before closing up the front of the
appliance. Follow the pilot lighting instructions
provided in the Homeowner's Care and Opera-
tion Instructions. For piezo igniter location see
Figure 22 (millivolt appliances only).
Note: The (pull-out) Lighting instructions label
can be found in the control compartment
(see Figure 20).
When fi rst lighting the appliance, it will take
a few minutes for the line to purge itself of
air. Once purging is complete, the pilot and
burner will light and operate as indicated in
the instruction manual. Subsequent lightings
of the appliance will not require such purging.
Inspect the pilot fl ame.
SIT and Honeywell Millivolt Appliance
Checkout
f i r e - p a r t s . c o m
The pilot fl ame should be steady, not lifting
or fl oating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" min (tip) of the
quick drop out thermocouple should be engulfed
in the pilot fl ame. The fl ame should project 1" (25
mm) beyond the hood at all three ports (Figure
23 - SIT, Figure 24 - Honeywell )
To light the burner; rotate the gas valve control
knob counterclockwise to the "ON" position
then turn "ON" the optional control switch,
if applicable (see Installation Accessories on
Page 19).
Observe the individual tongues of fl ame on
the burner. Make sure all ports are open and
producing fl ame evenly across the burner. If
any ports are blocked, or partially blocked,
clean out the ports.
GAS VALVE CONTROL COMPARTMENT
SIT Gas Valve
Shown with control
compartment door
removed
Piezo Igniter
Sit and Honeywell Millivolt Gas Valve
Showing Piezo Igniter Location (Each Unit is
Equipped with Only One of these Gas Valves)
Figure 22
SIT MILLIVOLT PILOT ASSEMBLY
Proper Pilot Flame Appearance
Hood
Thermocouple
Pilot
Nozzels
Thermopile
Figure 23
Replace logs if removed for pilot inspection.
To light the burner; turn "ON" the remote wall
switch and rotate the gas valve control knob
counterclockwise to the "ON" position.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HONEYWELL MILLIVOLT PILOT ASSEMBLY
Proper Pilot Flame Appearance
1/8" Min.
(3 mm)
Pilot
s
Nozzel
Honeywell
Gas Valve
Figure 24
Electronic Appliance Checkout
To light the burner, turn 'ON' the optional remote
wall switch and turn the gas control switch to
the "ON" position. Ensure the Igniter lights the
pilot. The pilot fl ame should engulf the fl ame
rod as shown in Figure 25.
Igniter Rod
ELECTRONIC PILOT ASSEMBLY
Proper Pilot Flame Appearance
Proper Flame
Adjustment
Pilot
Nozzels
Figure 25
Thermocouple
Igniter Rod
Hood
3/8" Min.
(9 mm)
Thermopile
3/8" to 1/2"
(9 -13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
13