Superior SSBV-3530CNM Installation Instructions Manual

Superior SSBV-3530CNM Installation Instructions Manual

B-vent ssbv-35/40 series

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
A French manual is available upon request. Order P/N 700,030CF
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 700,030CF.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes. This appliance is only for use with the type
of gas indicated on the rating plate. This appliance
is not convertible for use with other gases, unless
f i r e - p a r t s . c o m
a certifi ed kit is used.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
OTL Report No. 116-F-30-5
INSTALLATION
INSTRUCTIONS
B-VENT
SSBV-35/40 SERIES
B-VENT GAS FIREPLACES
P/N 700,030M REV. B 08/2005
MODELS
Millivolt Models
SSBV-3530CNM
SSBV-4035CNM
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides infl am-
mables dans le voisinage de cet appareil ou de tout
autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le batiment
où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifi é installeur, agence de service ou le fournis-
seur de gaz.
Electronic Models
SSBV-3530CNE
SSBV-4035CNE

Advertisement

Table of Contents
loading

Summary of Contents for Superior SSBV-3530CNM

  • Page 1 Millivolt Models Electronic Models codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance SSBV-3530CNM SSBV-3530CNE is not convertible for use with other gases, unless SSBV-4035CNM SSBV-4035CNE f i r e - p a r t s .
  • Page 2: Table Of Contents

    5 inch diameter double Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest 23,000 high wall vent pipe systems routed to the outside edition, or the Natural Gas and Propane Instal- SSBV-3530CNM 17,500 low atmosphere. lation Code, CSA B149.1 - latest edition. 29,000 high...
  • Page 3: Massachusetts Requirements

    Electronic Models - Electronic models have a Orifi ce Sizes - Sea Level to High Altitude Honeywell Millivolt Gas Valve fi xed rate gas valve. Input of electronic models (All Models) PIEZO is shown in Table 3. These appliances are tested and approved for IGNITER CONVERTIBLE PILOT...
  • Page 4 IMPORTANT WARNING WARNING These appliances must not be Do not attempt to alter or modify B-Vent appliances are not designed connected to a chimney or fl ue the construction of the appliance to operate in negatively pressured serving a separate solid fuel or its components.
  • Page 5: Location

    LOCATION Typical Installations In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the outside atmosphere and access to the fuel supply are also important. Consideration should be given to traffi c ways, furniture, draperies, etc., due to high surface temperatures (see illustrations).
  • Page 6: Minimum Clearances To Combustibles

    MINIMUM CLEARANCES TO COMBUSTIBLES APPLIANCE AND VENT CLEARANCES Maintain clearances from appliance to combus- Floor Protection /Hearth ExtensionThe appliance should be installed on top of a fully supported tible materials as detailed in Table 8 with the base extending the full width and depth of the unit. The appliance may be located on or near con- following exception: When the unit is installed ventional construction materials or raised on a platform of an appropriate height.
  • Page 7: Vent Termination Clearances

    Step 2. Routing Gas Line TYPICAL INSTALLATION SEQUENCE VENT TERMINATION CLEARANCES The typical sequence of installation follows, Gas vent caps are not permitted within 8 feet Route a gas line along the inside of the right side however, each installation is unique resulting (2.4 mm) of a vertical wall or similar obstruc- framing as shown in Figure 8.
  • Page 8: Fireplace Specifi Cations

    Rough Weight Framing Face Rough Framing Face (Unfinished Shown) Inside Chase (Unfinished Shown) 37”W x 17”D x 36”H H3337 SSBV-3530CNM 115 lb. Outside Chase (13.1 cu.ft) Important: Under no circum- 37”W x 17”D x 36”H H3338 SSBV-3530CNE 115 lb. stances can the fi replace top (13.1 cu.ft)
  • Page 9: Step 3. Position Unit In Framing

    Notes: * Note: The nailing fl anges, combustible mem- Type Type B-Vent 5 in. (127 mm) bers and screw heads located in areas directly • All appliances are factory-equipped with a adjacent to the nailing fl anges, are EXEMPT from fl...
  • Page 10: Step 5. Field Wiring

    4. Alternatively, the appliance may be operated B. Electronic Wiring (See Figures 17 & 18) Note: The electronic appliance must be con- without the use of the controls indicated in nected to the main power supply. step 1, solely by manipulating the gas valve control knob.
  • Page 11: Step 6. Optional Blower Installation

    Step 6. WIRING - Step 7. CONNECTING GAS LINE CAUTION OPTIONAL FORCED AIR BLOWER KIT Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure Ground supply lead must be con- FBK-100, FBK-200 and FBK250 Kits 19 illustrates two methods for connecting the nected to the wire attached to the (See Figure 17 for FBK-100, FBK-200 and...
  • Page 12: Step 8. Outside Air Kit Installation

    CAUTION Gas Flex Line Connector Never locate inlet where it can Valve 3/8" NPT x Flare Fitting be blocked by shrubs, snow 1/2" x 3/8" Flare Shut-off Valve drifts, etc. Never locate inlet in garage or any area where there is another fuel burning appliance 3/8"...
  • Page 13: Step 9. Checking Unit Operation

    Step 9. CHECKING APPLIANCE GAS VALVE CONTROL COMPARTMENT HONEYWELL MILLIVOLT PILOT ASSEMBLY OPERATION Proper Pilot Flame Appearance With the gas line installed, run initial system Thermocouple checkout before closing up the front of the SIT Gas Valve 1/8" Min. appliance. Follow the pilot lighting instructions Igniter Rod (3 mm) Hood...
  • Page 14: Step 10. Install Volcanic Stone

    SSBV-3530 - Install as Follows Step 10. INSTALL VOLCANIC STONE, WARNING GLOWING EMBERS AND LOGS Carefully position the ceramic fi ber logs into the If logs are not installed according fi rebox as shown in Figure 27. Logs should be 1.
  • Page 15: Log Placement Instructions

    MODEL SSBV-3530 Log Placement Instructions LOG SET Catalog Number H3367 * Item Description Log, Rear Log, Top Left Log, Center Log, Top Right * Item "letters" above correspond to photos Install the Embers, Volcanic Stone and Logs in the order shown here (1 through 5) and per the instructions on Page 14 Top fork on log (B) fi...
  • Page 16 MODEL SSBV-4035 Log Placement Instructions LOG SET Catalog Number H3368 * Item Description Log, Rear Log, Top Left Log, Center Log, Top Right * Item "letters" above correspond to photos Install the Embers, Volcanic Stone and Logs in the order shown here (1 through 5) and per the instructions on Page 14.
  • Page 17: Step 11. Installing Glass Door Panel

    Step 11. INSTALLING GLASS DOOR • An appliance operated with the air shutter Top Flange on opened too far, may have fl ames that appear Glass Door blue and transparent. These weak, blue and Glass Door transparent fl ames are termed anemic. WARNING •...
  • Page 18: Step 13. Spillage Test And Safety Limit Switch Operation

    Burner Air Shutter Adjustment Procedure Burner Flame Appearance Models - 1. Locate air shutter (see Figure 30 ). SSBV-3530 & SSBV-4035 Series 2. Light appliance (follow lighting procedure on lighting label in control compartment or see homeowners manual). 3. Allow the burner to operate for at least 15 min- utes while observing the fl...
  • Page 19: Step 14. Hood Installation

    5 - Replace the switch. GAS CONVERSION KITS Finishing Requirements Combustible 6 - Reinstall the switch/bracket assembly. Wall 7 - Reinstall the scoop and lintel. Framing Millivolt SIT Systems 8 - Reinstall the glass enclosure panel. Natural Gas To Propane Gas 9 - Reinstall the bottom control compartment Combustible Conversion Kits...
  • Page 20 Gas conversion kits are available to adapt the WARNING AVERTISSEMENT appliance from the use of one type of gas to the use of another. These kits contain all the This conversion kit shall be Cet équipement de conversion necessary components needed to complete the task including labeling that must be affi...
  • Page 21 b. Attach manometer to the manifold side pres- Pilot for Honeywell Millivolt Gas Valve sure test fi tting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for Orifi ce Strip Tab Position Identifi cation natural gas, and 10.0 inches water column For LP (propane gas) and Natural Gas Pilot for SIT Millivolt (2.49 kPa) for propane gas.
  • Page 22 Step 6. Electronic Appliances - See Figure 43 and replace the pilot orifi ce as fol- Step 9. Reassemble all removed components lows: Remove the Igniter assembly retainer clip, by reversing the procedures outlined Honeywell Systems and carefully remove the Igniter assembly. in the preceding steps.
  • Page 23 f i r e - p a r t s . c o m NOTE: THIS PAGE LEFT BLANK INTENTIONALLY.
  • Page 24 f i r e - p a r t s . c o m Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi...

This manual is also suitable for:

Ssbv-4035cnmSsbv-4035cneSsbv-3530cne

Table of Contents