Superior SSDVPF-CNE-B Installation Instructions Manual

Ssdv direct-vent gas fireplaces
Hide thumbs Also See for SSDVPF-CNE-B:

Advertisement

Quick Links

P/N 700031M Rev. F 01/2011
This manual is one of a set of two supporting this product.
Refer to P/N 725035M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 700031CF.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
WARNING / AVERTISSEMENT / AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
-
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
department.
- Installation and service must be performed by a
INSTALLATION INSTRUC TIONS
SSDV Direct-Vent
Gas Fireplaces
MODELS
MILLIVOLT:
SSDVST-CNM-B
SSDVPF-CNM-B
OTL Report No. 116-F-32-5
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
SSDVST-CNE-B
SSDVPF-CNE-B
Portland
US
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
ELECTRONIC:

Advertisement

Table of Contents
loading

Summary of Contents for Superior SSDVPF-CNE-B

  • Page 1 INSTALLATION INSTRUC TIONS SSDV Direct-Vent Gas Fireplaces P/N 700031M Rev. F 01/2011 This manual is one of a set of two supporting this product. MODELS Refer to P/N 725035M for Care and Operation Instructions. MILLIVOLT: ELECTRONIC: Ce manuel est disponible en francais, simplement SSDVST-CNM-B SSDVST-CNE-B en faire la demande.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PACKAGING GENERAL INFORMATION Packaging .........Page 2 The assembled vented gas fireplace heater is WARNING packaged with: Introduction ........Page 2 1 - One log set located in firebox area. General Information ......Page 2 Young children should be care- 2 - One envelope containing the literature Requirements for the fully supervised when they are...
  • Page 3 The appliance, when installed, must be electri- Note: Installation and repair should be done WARNING cally grounded and wired in accordance with by a qualified service person. The appliance local codes or, in the absence of local codes, should be inspected before use and at least Improper installation, adjust- with the National Electrical Code, ANSI/NFPA annually by a professional service person.
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    Gas Pressure - All Models Orifice Sizes - Sea Level to High Altitude (All Models) ON / OFF Switch Manifold Pressure Tables 3 and 4 show the appliances' gas Port Inlet These appliances are tested and approved for pressure requirements: Pressure installation at elevations of 0-4500 feet (0-1372 Port...
  • Page 5: Cold Climate Insulation

    COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
  • Page 6 VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances Termination Heights For Vents These instructions should be used as a Above Flat Or Sloped Roofs TERMINATION HEIGHTS FOR VENTS ABOVE guideline and do not supersede local codes FLAT OR SLOPED ROOFS Ref. NFPA 54 / ANSI Z223.1 in any way.
  • Page 7: Vent Termination Clearances

    EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS NOTE: Local Codes Or Regulations May Require Different Clearances. See Item D in the Text Below. NOTE: Location Of The Vent Termination Inside Exterior Wall Must Not Interfere With Access To The Corner Detail Electrical Service.
  • Page 8: Appliance And Vent Clearances

    MINIMUM CLEARANCES TO COMBUSTIBLES Appliance and Vent Clearances Maintain clearances from appliance to Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is used, combustible materials as detailed in Table do not block the lower control compartment access door. Any hearth extension used is for appearance 6, with the following exception: When the only and does not have to conform to standard hearth extension installation requirements.
  • Page 9: Detailed Installation Steps

    Step 1. FRAMING TYPICAL INSTALLATION SEQUENCE WARNING Frame these appliances as illustrated in Figures The typical sequence of installation is outlined Failure to position the parts in 12 and 13 on Pages 10 and 11. All framing below. However, each installation is unique accordance with these diagrams details must allow for a minimum clearance to and may result in variations to the steps...
  • Page 10: Fireplace And Framing Specifications

    FIREPLACE SPECIFICATIONS - SSDVST (SEE-THROUGH) • Inches (millimeters) SPECIFICATIONS • Minimum Framing Stud Size is 2 x 4 • See side views of fireplace below for Natural and Propane 37,500 gas line inlet location options. (MV Low 30,000) Gas BTU Input **25-1/4 11-3/8 (641)
  • Page 11 FIREPLACE SPECIFICATIONS - SSDVPF (PENINSULA VIEW) Fireplace Framing Specifications • Inches (millimeters) SPECIFICATIONS • Minimum Framing Stud Size is 2 x 4 • See right side viewsof fireplace below for gas line inlet location options. Natural & Propane 37,500 inches (millimeters) **25-1/4 11-3/8 (MV Low 30,000)
  • Page 12: Step 2. Routing Gas Line

    Step 2. ROUTING GAS LINE Proper Sizing of Gas Line Notes: • All appliances are factory-equipped with a Properly size and route the gas supply line Route a gas line along the inside of the right flexible gas line connector and 1/2 inch shutoff from the supply regulator to the area where valve (see Figure 47 on Page 27).
  • Page 13: Step 3. Install The Vent System

    Step 3. INSTALL THE VENT SYSTEM Vent Seal Cap Insulation General Information These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CSA-B149.1 in Canada.
  • Page 14: Vertical Termination Systems

    VERTICAL TERMINATION SYSTEMS (ROOF) VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART Nominal Nominal Section See Figure 18 and Figures 27 to 31 (Pages 17 Length (inches) Section Length and 18) and their associated Vertical Vent Tables i t c (inches) Net Section 4 ½...
  • Page 15 Vertical (offset) Installation D. Install firestop / spacer at ceiling - When B. Attach vent components to appliance - Se- using Secure Vent, use SV4.5VF firestop / cure Vent SV4.5 direct-vent system compo- Analyze the vent routing and determine the spacer at ceiling joists;...
  • Page 16 Use a carpenter’s level to measure from a SV4.5CGV-1 SV4.5FA or constant surface and adjust the support straps Termination SV4.5FB Flashing Storm as necessary. and SV4.5SC Collar Storm Collar It is important to maintain the required clear- ances to combustibles: 1" (25 mm) at all sides 1”...
  • Page 17: Vertical Vent Figures And Tables

    VERTICAL VENT FIGURES/TABLES Table A When using Secure Flex, use Firestop Notes: V Minimum H Maximum / Spacer SF4.5VF • Secure Vent™ (rigid vent pipe) is shown in the Figures; Secure Flex™ (flexible vent feet (meter) feet (meter) pipe) may also be used. (0.610) (0.305) •...
  • Page 18 VERTICAL VENT FIGURES / TABLES (CONTINUED) Table C Maximum H Maximum V Minimum feet (meter) feet (meter) feet (meter) Ceiling Firestop / Spacer (1.524) (0.610) (0.305) (SV4.5VF) (3.048) (1.219) (0.610) (4.572) (1.829) (0.914) (6.096) (2.438) (1.219) Wall Firestop/ V + V 1 + H + H 1 = 40 feet (12.2 m) Max Spacer (SV4.5HF) H = 8 feet (2.438 meters) Max.
  • Page 19: Horizontal Termination System

    Push the vent component against the previous Support Horizontal / Inclined Run Building section until it fully engages, then twist the Brackets Support component clockwise running the dimples Framing down and along the incline channels until they SV4.5HT-2 seat at the end of the channels. This seating SV4.5E90 Termination Elbow...
  • Page 20 J. Assemble vent run to exterior wall - If not previously measured, locate the center of the To help minimize water infiltration it is vent at the exterior wall. Prepare an opening recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior as described in Step B.
  • Page 21: Horizontal Vent Figures And Tables

    See Table 9 as an aid in venting component selection for a particular range of exterior wall thicknesses. Square termination Venting Components Required for Various Exterior Wall Thick- (SV4.5HT-2) shown. H = 28 in. (711 mm) Maximum nesses, when using Square Termination Kit (SV4.5HT-2) Vent Components Required Exterior Wall Thickness - inches (mm) 21 in.
  • Page 22 HORIZONTAL VENT FIGURES / TABLES (CONTINUED) Table F V Minimum Maximum H Maximum feet (meter) feet (meter) feet (meter) (1.524) (0.610) (0.305) (3.048) (1.219) (0.610) (4.572) (1.829) (0.914) Wall Firestop/ (6.096) (2.438) (1.219) Spacer (SV4.5HF) V + H + H 1 = 40 feet (12.2 m) Max H = 8 feet (2.438 meters) Max.
  • Page 23 HORIZONTAL VENT FIGURES / TABLES (CONTINUED) When using Secure Flex, use Firestop / Spacer SF4.5VF Wall Firestop / Spacer (SV4.5HF) When using Secure Flex, use Firestop / Spacer SF4.5HF Note: See Table 9 as an aid in venting component selection for a particular range of exterior wall thicknesses.
  • Page 24: Venting Using Flexible Vent Pipe

    VERTICAL OR HORIZONTAL VENTING USING Flex Vent NOTE: Outer pipe is pulled away to show SECuRE FLEX KITS AND COMPONENTS the detail of the inner pipe. Securing Screw - 3 places, equally spaced, just below Secure Flex™ venting kits and components gear clamp.
  • Page 25: Step 4. Field Wiring

    Refer to Section A for millivolt appliances and Step 4. FIELD WIRING Install OFF/ON Switch Section B for electronic appliances. The gas (millivolt models) valve is set in place and pre-wired at the factory CAUTION 1. Connect the 2 wires (provided in Electrical on both models.
  • Page 26: Step 5. Optional Blower Kit Wiring

    Step 5. WIRING - OPTIONAL FORCED AIR 5. Install a field-provided strain relief in the CAUTIONS cabinet knockout opening for the protection BLOWER KIT of the power supply wires. • Remove the carton support from 6. Connect the power supply wires to the FBK-100, FBK-200 and FBK-250 Kits receptacle as shown in Figure 46 on Page the control compartment before...
  • Page 27: Step 6. Connecting Gas Line

    Step 6. CONNECTING GAS LINE Gas Flex Line Connector All codes require a shut-off valve mounted in GAS CONNECTION 3/8" NPT x the supply line. The orientation of the shut-off 1/2" x 3/8" Flare Valve valve should face the front. Figure 47 illustrates Flare Fitting Shut-off Valve two methods for connecting the gas supply.
  • Page 28: Step 7. Verifying Appliance Operation

    TEST ALL CONNECTIONS FOR GAS LEAKS Millivolt Appliance Checkout Step 8. INSTALLING LOG SET, VOLCANIC (FACTORY AND FIELD): STONE AND GLOWING EMBERS The pilot flame should be steady, not lifting or floating. Flame should be blue in color with WARNING WARNING traces of orange at the outer edge.
  • Page 29 LOG AND VOLCANIC STONE INSTALLATION Install the unitized log set: BURNER POSITIONING PROCEDURE: NOTE: INSTALL REAR BURNER FIRST, a. The bottom of the log set is notched to ac- THEN FRONT BURNER. The log set foam package is located in the firebox commodate the pilot.
  • Page 30: Step 9. Installing Glass Door

    Removing Glass Enclosure Panels Step 9. INSTALLATION AND REMOVAL Step 10. BURNER ADJUSTMENTS (see Figure 56) OF GLASS DOOR Flame Appearance and sooting 1. Remove the top louver assembly by lifting it Proper flame appearance is a flame which is up and pulling it out.
  • Page 31: Step 11. Hood Installation

    Burner Air Shutter Adjustment Procedure Air Shutter Adjusting Burner Air Shutter WARNINGS Venturi Opening Tube ***Main Burner Factory Air Shutter • Air shutter adjustment should Orifice Opening Setting - All Models only be performed by a quali- fied professional service Natural Gas Propane Gas inches (millimeters)
  • Page 32: Step 12. Attaching Safety-In-Operation Warnings

    Step 12. ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY-IN-OPERATION APPOSITION DES MISES EN GARDE RELATIVES COLOCACIóN DE ADVERTENCIAS DE WARNINGS à...
  • Page 33: Installation Accessories

    INSTALLATION ACCESSORIES Item Cat. No. Model Description H1968 SV4.5HT-2 Horizontal Square Termination With Firestop / spacer (H2246) & Adapter (74L61) H2152 SV4.5CGV-1 Vertical Termination Cap 77L70 SV4.5L6 6 Inch (152 mm) Vent Section 77L71 SV4.5L12 12 Inch (305 mm) Vent Section 77L72 SV4.5L24 24 Inch (610 mm) Vent Section...
  • Page 34 Item Cat. No. Model Description H1969 SF4.5HT-2 Horizontal Square Termination (without flex) 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) 77L88 SFKIT18S Flex Square Term. (with 18 inch [457 mm] * compressed flex) 77L89 SFKIT24S Flex Square Term.
  • Page 35: Gas Conversion Kits

    INSTALLATION INSTRUCTIONS GAS CONVERSION KITS Step 1. TURN OFF THE GAS SUPPLY TO THE WARNING APPLIANCE and disconnect power supply at the circuit breaker. Ensure appliance is cold. This conversion kit shall be installed by a qualified service agency in accor- CAUTION: THE GAS SUPPLY SHALL BE dance with the manufacturer’s instructions and all applicable codes and SHUT OFF PRIOR TO DISCONNECTING THE...
  • Page 36 Electronic Appliances SIT Millivolt Gas Valve Pilot Pilot Assembly Step 7. Honeywell Electronic Valves - See Orifice Figure 63 and the instructions provided with Igniter Assembly the kit. Remove the slotted cap screw, o-ring, Pressure pressure-regulating adjusting screw and spring. Regulator Retain all parts for possible later use.
  • Page 37 BURNER POSITIONING BURNER ORIFICE NOTE: INSTALL REAR BURNER FIRST, THEN FRONT BURNER. BURNER BRACKET A REAR BURNER PORTS Figure 65 Step 10. Reassemble the remaining compo- nents by reversing the procedures outlined in the preceding steps. PILOT Step 11. Attach the conversion label provided BURNER in the conversion kit to the rating plate on the appliance.
  • Page 38 NOTES...
  • Page 39 NOTES...
  • Page 40 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2005 Lennox Hearth Products P/N 700031M REV.

This manual is also suitable for:

Ssdvpf-cnm-bSsdvst-cne-bSsdvst-cnm-b

Table of Contents