Step 13. Spillage Test And Safety Limit Switch Operation - Superior SSBV-3530CNM Installation Instructions Manual

B-vent ssbv-35/40 series
Table of Contents

Advertisement

Burner Air Shutter Adjustment Procedure
1. Locate air shutter (see Figure 30 ).
2. Light appliance (follow lighting procedure on
lighting label in control compartment or see
homeowners manual).
3. Allow the burner to operate for at least 15 min-
utes while observing the fl ame continuously
to ensure that the proper fl ame appearance
has been achieved (see Figure 31 or 32). If
the following conditions are present, adjust
accordingly.
• If flame appears weak or sooty, adjust
the air shutter, incrementally, to a more
open position until the proper fl ame
appearance is achieved.
• If fl ame stays lowered blue, adjust the
air shutter, incrementally, to a more
closed position until the proper fl ame
appearance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position and the burner OFF/ON switch
OFF (& remote switches, if applicable).
5. When satisfi ed that the burner fl ame appear-
ance is normal, re-install the lower control
compartment door then proceed to fi nish
f i r e - p a r t s . c o m
the installation.
Set Screw - Factory Located in the Natural Gas
Position; Relocate Set Screw for LP/Propane Gas
in the Alternate Position. See Table for Air Shut-
ter Openings for these Set Screw Locations.
Main Burner Factory Air Shutter
Opening Setting - Inches (millimeter)
Model
Natural
Gas
1/16"
SSBV-3530
(1.58 mm)
1/16"
SSBV-4035
(1.58 mm)
Figure 30
18
Figure 31
Step 13. VENT SPILLAGE TEST
After appliance installation, perform this spill-
age test to verify that proper venting conditions
exist:
1 - Place unit in its normally-operated condi-
tion, that is, with the glass enclosure panel
in place.
2 - Close all doors and windows in the room.
Turn on all exhaust fans in the house.
3 - Light the appliance.
4 - Wait 15 minutes.
5 - To check for venting action, start by
holding a smoke producing device within
an inch of one edge (side edge, not top or
bottom edge) of one glass enclosure panel.
The smoke should be drawn toward the edge
of the glass enclosure panel. Continue the
test by moving the smoke producing device
along the entire length of both side-edges of
the glass door.
6 - If the smoke is not drawn towards the
edges of the glass door turn off the appliance
and call a qualifi ed service technican.
Propane
Manually-Reset Spill switch (limit disc)
Gas
ALLOW APPLIANCE TO COOL COMPLETELY
1/4"
BEFORE ACCESSING AND RESETTING
(6.35 mm)
This appliance is equipped with a manually-
1/4"
reset blocked fl ue spill switch (limit disc).
(6.35 mm)
Refer to Figure 32 to 35 for its location. If,
during appliance operation, the fl ame goes
out (independently of the burner on/off wall
switch), it may be due to the operation of this
spill switch (limit disc). First allow the appli-
ance to cool.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Burner Flame Appearance Models -
SSBV-3530 & SSBV-4035 Series
Remove top louver panel. Then reset the spill
switch (limit disc) by pushing the red reset
button, located between the wire terminals, on
the back of the switch. See Figure 32.
The appliance should then relight and remain
lit. Reinstall top louver panel. If the appliance
does not relight, turn off the appliance and call
for a qualifi ed service technician.
To replace the blocked fl ue spill switch (limit
disc) refer to Figures 32, 33 & 34:
NOTE - This procedure should only be performed
by a qualifi ed service technician.
Important - Turn electrical power off before
beginning this procedure.
1 - Remove the bottom control compartment
access panel (see Figure 20 on Page 12).
Remove the glass enclosure panel (see
Glass Door Panel Removal Instructions
on Page 17).
2 - Remove the lintel securing screws (3) and
then remove the lintel. One of the lintel cabinet
top holes is shown in Figure 33).
3 - Remove the scoop securing screws (3) and
then remove the scoop. See Figure 33.
4 - Remove the safety switch bracket securing
screws (2), and pull the switch/bracket
assembly, with low voltage wires attached,
through the side panel slot into the fi rebox.
See Figure 34.