Figure 37. Universal rack connector
b. On the inside of the racks, facing out, mount the connectors at the appropriate height to the right
and left rack posts. Mount them in the middle hole of the height unit (the middle of a height unit
is the hole between two wide and neighboring division bars) in both front and back. The four
screw holes must align with the holes on your rack. If they do not, the blocks are not in the
correct location. See Figure 38 and Figure 39 on page 44.
Note: If the connectors are installed incorrectly, the screws on the connectors do not match the
holes on the frames. The circles in the graphics highlight the mismatch.
Figure 38. Incorrect connector locations
43