Table 36. Warning events (continued)
Event Code
Message Text and Description
4091
Auto calibration of one or more modules
failed. Adjustment out of range
4093
Could not obtain an IP address from DHCP
server.
4095
Library test failed. Not enough valid
cartridges available for testing.
4098
System time synchronization with SNTP
failed.
4099
An unexpected reset of accessor was
detected.
4113
Move from drive failed.
4117
Drive disabled because no power supply
available.
4119
Drive disabled because internal IP address
unknown.
4120
No empty drive available for system test.
4121
No compatible media available for system
test.
4122
No cartridge available for slot to slot
exerciser test.
4123
No empty slot available for slot to slot
exerciser test.
4124
Drive or media statistics could not be
retrieved when the tape was unloaded.
4126
Cartridge was found in inaccessible slot of
lowermost unit.
Details and Solution
v The library must be recalibrated.
v Ensure that the library firmware is up to date.
v This event indicates that one or more of the
gray calibration targets on the library
magazines could not be used in calibration.
v Inspect the calibration targets in each module
and then repeat the auto-calibration routine
with the Management GUI.
v Check the network configuration settings and
check if the DHCP server is reachable.
v Use the network configuration menu or
unplug the network cable and plug it in after a
few seconds to trigger an automatic
reconfiguration of the network interface.
Load the cartridges into the library.
Check for valid SNTP server address in Time
configuration. If correct, ensure that the server is
reachable from your network and not blocked by
a firewall.
Ensure that the spooling cable is fully seated in
the base module and connected correctly to the
accessor assembly. If the error recurs, replace the
accessor assembly.
Check for labels or cartridge misalignments that
prevents the cartridge from coming out of the
slot or drive.
Remove all affected drives, insert, and power up
at least one power supply to the failing module.
Wait 10 seconds and put the drives back into the
module.
v Remove affected drive, wait 10 seconds, and
put it back into the module.
v Restart Library stack.
Make sure that at least one empty drive and one
compatible cartridge are available.
Make sure that at least one empty drive and one
compatible cartridge are in the drive.
Make sure that at least one cartridge and one
empty slot are in the library.
Make sure that at least one cartridge and one
empty slot are in the library.
Check for more warning tickets. Replace media if
media-related tape alert flags reported.
Bottom slots from the lowermost unit are
inaccessible to the accessor. Place the cartridge in
an upper slot.
91
Troubleshooting