Maytag ALY1680BD series Service Manual page 11

Rv freestanding gas ranges and gas cooktops
Hide thumbs Also See for ALY1680BD series:
Table of Contents

Advertisement

Troubleshooting Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power and gas before servicing, unless
testing requires power and/or gas.
Problem
Gas odor.
Oven slow to heat, poor
baking results, poor burner
ignition, pilot won't stay lit,
carbon on pilot shield, flame
too high or too low.
NOTE: Due to vibrations that occur when traveling in a recreational vehicle, gas connections may loosen.
Periodically check all gas connections and gas fittings for leaks.
TESTING FOR GAS LEAKS:
©2005 Maytag Services
!
W ARNING
Possible Cause
Gas leak ....................................................
Loose fittings .............................................
Pressure regulator..................................... • Test pressure regulator, see Chapter
Never test for gas leaks using an open flame.
To test for a gas leak, apply a non-corrosive leak detection fluid to all joints and
fittings in the gas connection between the supply line, shut-off valve, and range or
cooktop. Include gas fittings and joints in the range or cooktop if connections were
disturbed during installation. Bubbles appearing around fittings and connections
indicates a leak. If a leak is present, turn off supply line gas shut-off valve, tighten
connections, turn on the supply line gas shut-off valve, and retest for leaks. When
finished, wipe off all residue.
• Check all gas connections for leaks
(see note below).
• Check all gas fittings for leaks.
5, "Testing Procedures."