Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power and gas before servicing, unless
testing requires power and/or gas.
Component Testing Procedures
Illustration
Burner, bake
(Not applicable to
cooktop models.)
Burner, pilot
(Not applicable to
cooktop models.)
Thermostat, gas
(Copreci)
(Not applicable to
cooktop models.)
Spark ignitor, top
burners
Ignitor, Piezo
(All models except
ALZ8590AD*,
CG11000AD*,
CPL1110AD*,
YPL1110AD*,
CLY2210BD*,
CLY1610BD*)
Electrode, top burner
electrode (Models
ALZ8580AD*,
ALZ8589AD*)
Regulator, pressure
Valve, top burner
(6.5K burners)
Valve, top burner
(9.1K burner)
Burner, top rear,
sealed (6.5K burners)
Burner, top front,
sealed (9.1K burner)
Burner, top, sealed
(Models
ALY1680BD*,
ALY2280BD*,
ALY2289BD*,
ALZ8580AD*,
ALZ8589AD*,
ALZ8590AD*)
12
!
Component
Verify gas is supplied.
Check for obstructions, contamination
in ports or damage .................................
Verify gas is supplied.
Check for obstructions, contamination
in ports or damage .................................
Verify gas is supplied ............................. Gas is supplied.
Measure resistance from tip of spark
ignitor to wire terminal ............................ Continuity.
Verify operation by rotating dial in the
direction indicated on the knob ............... Ignitor clicks and top burner spark ignitor
Measure resistance from tip of
electrode to wire terminal ....................... Continuity.
Verify gas pressure (WCP)..................... 10" LP/Propane.
Verify gas is supplied ............................. Gas is supplied.
Verify gas is supplied ............................. Gas is supplied.
Verify gas is supplied .............................
Check for obstructions or
contamination in burner ports .................
Verify gas is supplied .............................
Check for obstructions or
contamination in burner ports .................
Verify gas is supplied .............................
Check for obstructions or
contamination in burner ports .................
WARNING
Test Procedure
16023515
Results
Air shutter opening: .438" to .498".
Blue flame with some yellow tipping is
normal (burner should not soot).
Replace if punctured or torn.
Orifice diameter: .0078" to .0086".
Blue flame with some yellow tipping is
normal (burner should not soot).
Replace if punctured or torn.
emits a spark.
Gas is supplied.
Clean/remove any foreign objects.
Gas is supplied.
Clean/remove any foreign objects.
Gas is supplied.
Clean/remove any foreign objects.