Intel MFSYS25V2 Tested Hardware And Operating System List page 14

Modular server systems
Hide thumbs Also See for MFSYS25V2:
Table of Contents

Advertisement

Intel® Modular Server Systems
SSD (2.5" SATA interface)
Intel
X25-M
Intel
X25-M
Intel
320
Intel
320
Intel
320
Intel
320
Intel
320
Intel
320
Intel
320
Intel
320
Intel
320
Intel
320
Notes:
(1) Firmware revisions listed in this column are the minimum revision levels supported. As they become
available, listed drives with newer revisions of firmware are also supported. OEM specific ve rsions of drive
firmware are not supported. Hard drives within a storage pool are recommended to have the same level of
drive firmware. However, a storage pool consisting of drives with different firmware levels is supported as
long as the firmware meets minimum supported firmware revision requirements and firmware is not an OEM
specific version of firmware.
(2) MFSYS25V2 mixed SAS and SSD mix models validated are as follows: Mix combination was limited to one
physical SAS drive model and one SSD drive model. Mixing of drive models within a storage pool is not
supported. The mixed drive models below contain the configuration which has been validated. Other
combinations of a single SSD drive model and a single SAS drive model although not validated, are
supported.
2 SSD drives – slots 1,2
4 SSD drives – slots 1-4
(3) SD (Similar Drive) -The hard disk drive is supported, but not tested. This hard drive model/capacity has not
been tested with this server board, but Intel will support it based on successful testing of a larger capacity
hard drive from the same hard drive family. Intel has high confidence that this hard drive will function
correctly with the server board. This drive uses the exact same firmware and drivers as a larger capacity
hard drive that has been successfully tested with this server board. The only difference between this drive
and the one that was used in testing is the storage capacity. Intel provides the same level of support for all
hard drives listed in this document, regardless of whether the drive was tested or not. Customers should
14
SSDSA2M160G2
SSDSA2M080G2
SSDSA2BW080G3
SSDSA2CW080G3
SSDSA2BW120G3
SSDSA2CW120G3
SSDSA2BW160G3
SSDSA2CW160G3
SSDSA2BW300G3
SSDSA2CW300G3
SSDSA2BW600G3
SSDSA2CW600G3
12 SAS drives - slots 3-14
10 SAS drives - slots 5-14
160GB
02G9
UFU 10.1
80GB
02G9
UFU 10.1
80GB
4PC10302
UFU 10.4
80GB
4PC10302
UFU 10.4
120GB
4PC10302
UFU 10.4
120GB
4PC10302
UFU 10.4
160GB
4PC10302
UFU 10.4
160GB
4PC10302
UFU 10.4
300GB
4PC10302
UFU 10.4
300GB
4PC10302
UFU 10.4
600GB
4PC10302
UFU 10.4
600GB
4PC10302
UFU 10.4
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Requires
AXXTM3SATA
Revision 1.0

Advertisement

Table of Contents
loading

Table of Contents