Code
Description
36
Plug detection in M1 motor
socket
37
Plug detection in M2 motor
socket
38
Plug detection in M3 motor
socket
61
Actuator changed
55
Synchronization
group 1
56
Synchronization
group 2
67
High voltage
70
Motor configuration changed
71
Anti-Pinch
changed
81
Internal error
Danger: the PowerFail detection identifies mains power breakdowns
and saves all relevant data before the voltage falls below a critical
threshold.
In some exceptional cases this storage is not possible and the error E81
is shown on the handswitch display (if available) and the COMPACT
clicks three times.
To rectify this error, a manual reset is necessary (see page 20).
Remedy
Plug in the correct motor to the motor
socket that shows the error.
Reset all motors.
lost
motor
Remove load from desktop.
Reset all motors;
If error occurs after reset again, contact
lost
motor
customer service
Unplug power cord and contact the
customer service.
See chapter 4.3.3
configuration
See chapter 4.3.6 to activate or deactivate
the anti-pinch configuration
Make a manual reset.
Unplug power cord and plug it in again
after a few seconds.
If this error occurs frequently, unplug the
power cord and contact the customer
service.