Sage The Oracle BES980 Quick Manual page 21

Hide thumbs Also See for The Oracle BES980:
Table of Contents

Advertisement

Available languages

Available languages

CARE & CLEANING
DESCALE (dESc)
NOTE
Even if you used the provided water filter,
we recommend you to descale if there is
scale build-up in the water tank.
Only descale via the descale menu.
1 – Prepare for Descale
a. Empty the drip tray and insert into position.
b. Turn the machine off and allow to cool for at
least 4 hours. With the machine off, press and
hold the 1 CUP button, then press and hold
the POWER button together for
3 seconds. rSEt will appear on the LCD.
THEN PRESS
& HOLD
c. Rotate SELECT dial until 'dESC" appears on
LCD and press the dial to confirm.
SELECT
SELECT
SELECT
TEMP TEXTURE
TEMP TEXTURE
TEMP TEXTURE
POWER
SELECT
SELECT
SELECT
TEMP TEXTURE
TEMP TEXTURE
TEMP TEXTURE
2 – Empty Boilers
a. Remove the grey silicone cover on the lower
front panel marked DESCALE ACCESS.
b.
REMOVE
c. Place a cloth over the drip tray to prevent
steam escaping.
d.
e. Use a flat head screw driver to rotate the
right valve counter-clockwise SLOWLY
until fully open. As the valve opens, steam
may be released.
NOTE
If there's no water released into the drip tray,
press and hold the 1 CUP button for
3 seconds. This will release water from the
boiler.
When the water is completely empty, close the
valve by rotating screws clock-wise until seated.
Do not overtighten screws to avoid damages
to the valves.
EN
21

Advertisement

Table of Contents
loading

Table of Contents